Your browser doesn't support javascript.
loading
Assessment of a polyelectrolyte multilayer film coating loaded with BMP-2 on titanium and PEEK implants in the rabbit femoral condyle.
Guillot, R; Pignot-Paintrand, I; Lavaud, J; Decambron, A; Bourgeois, E; Josserand, V; Logeart-Avramoglou, D; Viguier, E; Picart, C.
Afiliação
  • Guillot R; CNRS, UMR 5628, LMGP, 3 parvis Louis Néel, F-38016 Grenoble, France; Université de Grenoble Alpes, Grenoble Institute of Technology, 3 parvis Louis Néel, F-38016 Grenoble, France.
  • Pignot-Paintrand I; CNRS, UMR 5628, LMGP, 3 parvis Louis Néel, F-38016 Grenoble, France; Université de Grenoble Alpes, Grenoble Institute of Technology, 3 parvis Louis Néel, F-38016 Grenoble, France.
  • Lavaud J; Institute Albert Bonniot, INSERM U823, ERL CNRS3148, Grenoble, France.
  • Decambron A; CNRS, UMR 7052, B2OA, University Paris Diderot, Sorbonne Paris Cité, F-75010 Paris, France; Université Paris-Est, Ecole Nationale Vétérinaire d'Alfort, Maisons-Alfort Cedex, France.
  • Bourgeois E; CNRS, UMR 5628, LMGP, 3 parvis Louis Néel, F-38016 Grenoble, France; Université de Grenoble Alpes, Grenoble Institute of Technology, 3 parvis Louis Néel, F-38016 Grenoble, France.
  • Josserand V; Institute Albert Bonniot, INSERM U823, ERL CNRS3148, Grenoble, France.
  • Logeart-Avramoglou D; CNRS, UMR 7052, B2OA, University Paris Diderot, Sorbonne Paris Cité, F-75010 Paris, France.
  • Viguier E; ICE, UPSP 2011.03.101, Campus vétérinaire de Lyon, VetAgro Sup, Marcy l'étoile 69280, France.
  • Picart C; CNRS, UMR 5628, LMGP, 3 parvis Louis Néel, F-38016 Grenoble, France; Université de Grenoble Alpes, Grenoble Institute of Technology, 3 parvis Louis Néel, F-38016 Grenoble, France. Electronic address: catherine.picart@grenoble-inp.fr.
Acta Biomater ; 36: 310-22, 2016 05.
Article em En | MEDLINE | ID: mdl-26965394
UNLABELLED: The aim of this study was to evaluate the osseointegration of titanium implants (Ti-6Al-4V, noted here TA6V) and poly(etheretherketone) PEEK implants induced by a BMP-2-delivering surface coating made of polyelectrolyte multilayer films. The in vitro bioactivity of the polyelectrolyte film-coated implants was assessed using the alkaline phosphatase assay. BMP-2-coated TA6V and PEEK implants with a total dose of 9.3µg of BMP-2 were inserted into the femoral condyles of New Zealand white rabbits and compared to uncoated implants. Rabbits were sacrificed 4 and 8weeks after implantation. Histomorphometric analyses on TA6V and PEEK implants and microcomputed tomography on PEEK implants revealed that the bone-to-implant contact and bone area around the implants were significantly lower for the BMP-2-coated implants than for the bare implants. This was confirmed by scanning electron microscopy imaging. This difference was more pronounced at 4weeks in comparison to the 8-week time point. However, bone growth inside the hexagonal upper hollow cavity of the screws was higher in the case of the BMP-2 coated implants. Overall, this study shows that a high dose of BMP-2 leads to localized and temporary bone impairment, and that the dose of BMP-2 delivered at the surface of an implant needs to be carefully optimized. STATEMENT OF SIGNIFICANCE: The presentation of growth factors from material surfaces currently presents significant challenges in academia, clinics and industry. Applying osteoinductive factors to different types of implants, made of metals or polymers, may improve bone repair in difficult situations. Here, we show the effects of an osteoinductive coating made of polyelectrolyte multilayer films on two widely used materials, titanium TA6V alloys and PEEK implants, which were implanted in the rabbit femoral condyle. We show that a too high dose of BMP-2 delivered from the screw surface has a negative short-term effect on bone regeneration in close vicinity of the screw surface. In contrast, bone formation was increased at early times in the empty spaces around the screw. These results highlight the need for future dose-dependence studies on bone formation in response to osteoinductive coatings.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polietilenoglicóis / Titânio / Parafusos Ósseos / Teste de Materiais / Materiais Revestidos Biocompatíveis / Proteína Morfogenética Óssea 2 / Fêmur / Cetonas Limite: Animals Idioma: En Revista: Acta Biomater Ano de publicação: 2016 Tipo de documento: Article País de afiliação: França País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polietilenoglicóis / Titânio / Parafusos Ósseos / Teste de Materiais / Materiais Revestidos Biocompatíveis / Proteína Morfogenética Óssea 2 / Fêmur / Cetonas Limite: Animals Idioma: En Revista: Acta Biomater Ano de publicação: 2016 Tipo de documento: Article País de afiliação: França País de publicação: Reino Unido