Your browser doesn't support javascript.
loading
The diagnostic value of magnetic resonance urography using a balanced turbo field echo sequence.
Çifçi, Egemen; Çoban, Gökçen; Çiçek, Tufan; Gönülalan, Umut.
Afiliação
  • Çifçi E; Department of Radiology, Baskent University Faculty of Medicine, Hocacihan mah. Saray cad., No:1 Selcuklu, Konya, Turkey, 42080. drecifci@gmail.com.
  • Çoban G; Department of Radiology, Baskent University Faculty of Medicine, Hocacihan mah. Saray cad., No:1 Selcuklu, Konya, Turkey, 42080.
  • Çiçek T; Department of Urology, Baskent University Faculty of Medicine, Konya, Turkey.
  • Gönülalan U; Department of Urology, Baskent University Faculty of Medicine, Konya, Turkey.
Eur Radiol ; 26(12): 4624-4631, 2016 Dec.
Article em En | MEDLINE | ID: mdl-26984432
OBJECTIVES: The aim of the study was to compare the inter-observer variability and the accuracy of magnetic resonance urography (MRU) using a thin sectional balanced-turbo field echo (B-TFE) sequence for detecting ureteral calculi and to determine the effect of additional factors (size, density and location of the calculus) on the sensitivity and specificity of the MRU. MATERIALS & METHODS: MRU and CT images were evaluated independently by two radiologists according to presence, density and localization of calculi. The degrees of inter-rater agreement for categorical items were evaluated by the Kappa coefficient. RESULTS: According to the 1st and 2nd observers, the sensitivity of MRU was 65.9 %, 71.8 % and the specificity of MRU was 95.9 %, 100 %, respectively. Inter-observer agreement was 84.6 % for stone detection. The larger size had a better effect on detectability (p < 0.05). Also, the higher density had a better impact on detectability (p < 0.05). CONCLUSION: Our study has shown that B-TFE MRU was useful to detect ureteral calculi. However, B-TFE MRU has low sensitivity and high specificity in comparison with CT images. MRU is a reasonable alternative imaging technique for follow-up periods of selective groups like patients with large urinary stones, children or pregnant patients when ionizing radiation is undesirable. KEY POINTS: • According to 1st and 2nd observers, sensitivity of MRU was 65.9 %, 71.8 %, respectively. • According to 1st and 2nd observers, MRU specificity was 95.9 %, 100 %, respectively. • Interobserver agreement was found to be over 84 % for stone detection. • B-TFE sequence provides calculus follow-up without radiation. • Larger calculi and more dense calculi individually have the better effect on detectability.
Assuntos
Palavras-chave
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Urografia / Cálculos Ureterais Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged / Pregnancy Idioma: En Revista: Eur Radiol Assunto da revista: RADIOLOGIA Ano de publicação: 2016 Tipo de documento: Article País de publicação: Alemanha
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Urografia / Cálculos Ureterais Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged / Pregnancy Idioma: En Revista: Eur Radiol Assunto da revista: RADIOLOGIA Ano de publicação: 2016 Tipo de documento: Article País de publicação: Alemanha