Cardiac magnetic resonance imaging-based myocardial strain study for evaluation of cardiotoxicity in breast cancer patients treated with trastuzumab: A pilot study to evaluate the feasibility of the method.
Nakano, Shintaro; Takahashi, Masahiro; Kimura, Fumiko; Senoo, Taiki; Saeki, Toshiaki; Ueda, Shigeto; Tanno, Jun; Senbonmatsu, Takaaki; Kasai, Takatoshi; Nishimura, Shigeyuki.
Afiliação
  • Nakano S; Department of Cardiology, International Medical Center, Saitama Medical University, Saitama, Japan. snakano@saitama-med.ac.jp.
Cardiol J ; 23(3): 270-80, 2016.
Article em En | MEDLINE | ID: mdl-27173679
ABSTRACT

BACKGROUND:

Trastuzumab, used to treat breast cancer overexpressing human epidermal growth factor receptor 2, may be cardiotoxic. Cardiac magnetic resonance (CMR) imaging with myocardial strain studies has been used to evaluate subclinical biventricular myocardial changes, however, its clinical utility during chemotherapy has not been evaluated.

METHODS:

The clinical outcomes, CMR and cardiac biomarkers of 9 women aged 62.3 ± 12.6 years with early or locally advanced breast cancer were evaluated at baseline, and at 3, 6 and 12 months after the initiation of trastuzumab.

RESULTS:

None of the patients developed heart failure or elevated serum cardiac biomarkers. Global left ventricular (LV) peak systolic longitudinal and circumferential strains were significantly decreased at 6 months (longitudinal strains, -21.1 ± 1.7% [baseline] vs. -19.5 ± 1.0% [6 months], p = 0.039, and circumferential strains, -23.4 ± 1.8% [baseline] vs. -21.6 ± 2.5% [6 months], p = 0.036). These changes were analogous to those observed in the LV ejection fraction. Right ventricular (RV) free wall peak systolic circumferential strains were decreased at 6 months (-20.9% ± 2.4% [baseline] vs. -19.1% ± 2.3% [6 months], p = 0.049), whereas RV longitudinal strains and ejection fraction remained unchanged. The LV longitudinal strain was the most reproducible of the 4 peak strain parameters.

CONCLUSIONS:

The LV longitudinal and circumferential strains measured by CMR decreased during trastuzumab therapy, although their predictive value for later heart failure or association with RV parameters was not determined. These techniques may be a useful means of diagnosing and monitoring trastuzumab-related cardiotoxicity.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Função Ventricular Esquerda / Imagem Cinética por Ressonância Magnética / Trastuzumab / Miocárdio Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Female / Humans / Middle aged Idioma: En Revista: Cardiol J Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Função Ventricular Esquerda / Imagem Cinética por Ressonância Magnética / Trastuzumab / Miocárdio Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Female / Humans / Middle aged Idioma: En Revista: Cardiol J Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Japão