Your browser doesn't support javascript.
loading
Removal of micropollutants with coarse-ground activated carbon for enhanced separation with hydrocyclone classifiers.
Otto, N; Platz, S; Fink, T; Wutscherk, M; Menzel, U.
Afiliação
  • Otto N; Institute for Sanitary Engineering, Water Quality and Solid Waste Management, University of Stuttgart, Bandtäle 2, 70569 Stuttgart, Germany E-mail: nikolai.otto@iswa.uni-stuttgart.de.
  • Platz S; Institute for Sanitary Engineering, Water Quality and Solid Waste Management, University of Stuttgart, Bandtäle 2, 70569 Stuttgart, Germany E-mail: nikolai.otto@iswa.uni-stuttgart.de.
  • Fink T; Institute for Sanitary Engineering, Water Quality and Solid Waste Management, University of Stuttgart, Bandtäle 2, 70569 Stuttgart, Germany E-mail: nikolai.otto@iswa.uni-stuttgart.de.
  • Wutscherk M; Ökoservice GmbH, Abwasser- und Umwelttechnik, Köngener Straße 14, 73770 Denkendorf, Germany.
  • Menzel U; Institute for Sanitary Engineering, Water Quality and Solid Waste Management, University of Stuttgart, Bandtäle 2, 70569 Stuttgart, Germany E-mail: nikolai.otto@iswa.uni-stuttgart.de.
Water Sci Technol ; 73(11): 2739-46, 2016.
Article em En | MEDLINE | ID: mdl-27232411
One key technology to eliminate organic micropollutants (OMP) from wastewater effluent is adsorption using powdered activated carbon (PAC). To avoid a discharge of highly loaded PAC particles into natural water bodies a separation stage has to be implemented. Commonly large settling tanks and flocculation filters with the application of coagulants and flocculation aids are used. In this study, a multi-hydrocyclone classifier with a downstream cloth filter has been investigated on a pilot plant as a space-saving alternative with no need for a dosing of chemical additives. To improve the separation, a coarser ground PAC type was compared to a standard PAC type with regard to elimination results of OMP as well as separation performance. With a PAC dosing rate of 20 mg/l an average of 64.7 wt% of the standard PAC and 79.5 wt% of the coarse-ground PAC could be separated in the hydrocyclone classifier. A total average separation efficiency of 93-97 wt% could be reached with a combination of both hydrocyclone classifier and cloth filter. Nonetheless, the OMP elimination of the coarse-ground PAC was not sufficient enough to compete with the standard PAC. Further research and development is necessary to find applicable coarse-grained PAC types with adequate OMP elimination capabilities.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Poluentes Químicos da Água / Carvão Vegetal / Purificação da Água Tipo de estudo: Evaluation_studies Idioma: En Revista: Water Sci Technol Assunto da revista: SAUDE AMBIENTAL / TOXICOLOGIA Ano de publicação: 2016 Tipo de documento: Article País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Poluentes Químicos da Água / Carvão Vegetal / Purificação da Água Tipo de estudo: Evaluation_studies Idioma: En Revista: Water Sci Technol Assunto da revista: SAUDE AMBIENTAL / TOXICOLOGIA Ano de publicação: 2016 Tipo de documento: Article País de publicação: Reino Unido