Implementing the INTERGROWTH-21st fetal growth standards in France: a 'flash study' of the College Français d'Echographie Foetale (CFEF).
Ultrasound Obstet Gynecol
; 49(4): 487-492, 2017 Apr.
Article
em En
| MEDLINE
| ID: mdl-27516404
ABSTRACT
OBJECTIVES:
To assess potential differences in fetal size between the French population and the international population from the INTERGROWTH-21st (IG-21st ) Project and to measure the impact of switching to the IG-21st reference standards for fetal size.METHODS:
This was a nationwide cross-sectional study of fetal ultrasound biometry. Low-risk singleton pregnancies were recruited prospectively within the network of the national French College of Fetal Ultrasound, CFEF, over a 6-week period. Further selection was performed based on the criteria of the IG-21st Project in order to obtain a comparable population. Head circumference (HC) was used as the main fat-free skeletal measure of growth for comparison of French fetal size with that of the IG-21st population. The impact of switching to the IG-21st fetal growth standards was quantified by comparing Z-scores calculated using the IG-21st standards with those calculated using locally derived reference ranges for HC, abdominal circumference (AC) and femur length (FL).RESULTS:
Following selection, 4858 cases were analyzed. The distribution of HC demonstrated clear similarity between our French population and the IG-21st population our observed centile curves closely matched those of IG-21st and the Z-scores were close to 0 across gestational age. The IG-21st standards performed as well as did locally derived charts in terms of screening for small-for-gestational age by AC, while they identified significantly fewer small FL values than were expected and than did the locally derived charts.CONCLUSIONS:
Under strict selection criteria, fetal size in France is similar to that of the international population used in the IG-21st Project. The discrepancies in FL are unlikely to impact on prenatal management. Therefore, switching from locally derived reference ranges to the IG-21st standards appears to be a safe option. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Diagnóstico Pré-Natal
/
Ultrassonografia Pré-Natal
/
Desenvolvimento Fetal
/
Cabeça
Tipo de estudo:
Diagnostic_studies
/
Observational_studies
/
Prevalence_studies
/
Prognostic_studies
/
Risk_factors_studies
Limite:
Female
/
Humans
/
Pregnancy
País/Região como assunto:
Europa
Idioma:
En
Revista:
Ultrasound Obstet Gynecol
Assunto da revista:
DIAGNOSTICO POR IMAGEM
/
GINECOLOGIA
/
OBSTETRICIA
Ano de publicação:
2017
Tipo de documento:
Article
País de afiliação: