Your browser doesn't support javascript.
loading
Implementing the INTERGROWTH-21st fetal growth standards in France: a 'flash study' of the College Français d'Echographie Foetale (CFEF).
Stirnemann, J J; Fries, N; Bessis, R; Fontanges, M; Mangione, R; Salomon, L J.
Afiliação
  • Stirnemann JJ; Assistance Publique-Hôpitaux de Paris, Hôpital Necker-Enfants Malades, Paris, France.
  • Fries N; EA FETUS, 7328, Université Paris-Descartes, Paris, France.
  • Bessis R; Collège Français d'Echographie Foetale, CFEF, France.
  • Fontanges M; Collège Français d'Echographie Foetale, CFEF, France.
  • Mangione R; Collège Français d'Echographie Foetale, CFEF, France.
  • Salomon LJ; Collège Français d'Echographie Foetale, CFEF, France.
Ultrasound Obstet Gynecol ; 49(4): 487-492, 2017 Apr.
Article em En | MEDLINE | ID: mdl-27516404
ABSTRACT

OBJECTIVES:

To assess potential differences in fetal size between the French population and the international population from the INTERGROWTH-21st (IG-21st ) Project and to measure the impact of switching to the IG-21st reference standards for fetal size.

METHODS:

This was a nationwide cross-sectional study of fetal ultrasound biometry. Low-risk singleton pregnancies were recruited prospectively within the network of the national French College of Fetal Ultrasound, CFEF, over a 6-week period. Further selection was performed based on the criteria of the IG-21st Project in order to obtain a comparable population. Head circumference (HC) was used as the main fat-free skeletal measure of growth for comparison of French fetal size with that of the IG-21st population. The impact of switching to the IG-21st fetal growth standards was quantified by comparing Z-scores calculated using the IG-21st standards with those calculated using locally derived reference ranges for HC, abdominal circumference (AC) and femur length (FL).

RESULTS:

Following selection, 4858 cases were analyzed. The distribution of HC demonstrated clear similarity between our French population and the IG-21st population our observed centile curves closely matched those of IG-21st and the Z-scores were close to 0 across gestational age. The IG-21st standards performed as well as did locally derived charts in terms of screening for small-for-gestational age by AC, while they identified significantly fewer small FL values than were expected and than did the locally derived charts.

CONCLUSIONS:

Under strict selection criteria, fetal size in France is similar to that of the international population used in the IG-21st Project. The discrepancies in FL are unlikely to impact on prenatal management. Therefore, switching from locally derived reference ranges to the IG-21st standards appears to be a safe option. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Diagnóstico Pré-Natal / Ultrassonografia Pré-Natal / Desenvolvimento Fetal / Cabeça Tipo de estudo: Diagnostic_studies / Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Limite: Female / Humans / Pregnancy País/Região como assunto: Europa Idioma: En Revista: Ultrasound Obstet Gynecol Assunto da revista: DIAGNOSTICO POR IMAGEM / GINECOLOGIA / OBSTETRICIA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: França

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Diagnóstico Pré-Natal / Ultrassonografia Pré-Natal / Desenvolvimento Fetal / Cabeça Tipo de estudo: Diagnostic_studies / Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Limite: Female / Humans / Pregnancy País/Região como assunto: Europa Idioma: En Revista: Ultrasound Obstet Gynecol Assunto da revista: DIAGNOSTICO POR IMAGEM / GINECOLOGIA / OBSTETRICIA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: França