In-vivo validation of a new clinical tool to quantify three-dimensional myocardial strain using ultrasound.
Bouchez, S; Heyde, B; Barbosa, D; Vandenheuvel, M; Houle, H; Wang, Y; D'hooge, J; Wouters, P F.
Afiliação
  • Bouchez S; Department of Anesthesiology, Ghent University Hospital, De Pintelaan 185, 9000, Ghent, Belgium. stefaan.bouchez@ugent.be.
  • Heyde B; Laboratory on Cardiovascular Imaging and Dynamics, KU Leuven, Leuven, Belgium.
  • Barbosa D; Laboratory on Cardiovascular Imaging and Dynamics, KU Leuven, Leuven, Belgium.
  • Vandenheuvel M; Department of Anesthesiology, Ghent University Hospital, De Pintelaan 185, 9000, Ghent, Belgium.
  • Houle H; Ultrasound Division, Siemens Medical Solutions, Mountain View, CA, USA.
  • Wang Y; Ultrasound Division, Siemens Medical Solutions, Mountain View, CA, USA.
  • D'hooge J; Laboratory on Cardiovascular Imaging and Dynamics, KU Leuven, Leuven, Belgium.
  • Wouters PF; Department of Anesthesiology, Ghent University Hospital, De Pintelaan 185, 9000, Ghent, Belgium.
Int J Cardiovasc Imaging ; 32(12): 1707-1714, 2016 Dec.
Article em En | MEDLINE | ID: mdl-27535041
ABSTRACT
Three-dimensional (3D) strain analysis based on real-time 3-D echocardiography (RT3DE) has emerged as a novel technique to quantify regional myocardial function. The goal of this study was to evaluate accuracy of a novel model-based 3D tracking tool (eSie Volume Mechanics, Siemens Ultrasound, Mountain View, CA, USA) using sonomicrometry as an independent measure of cardiac deformation. Thirteen sheep were instrumented with microcrystals sutured to the epi- and endocardium of the inferolateral left ventricular wall to trace myocardial deformation along its three directional axes of motion. Paired acquisitions of RT3DE and sonomicrometry were made at baseline, during inotropic modulation and during myocardial ischemia. Accuracy of 3D strain measurements was quantified and expressed as level of agreement with sonomicrometry using linear regression and Bland-Altman analysis. Correlations between 3D strain analysis and sonomicrometry were good for longitudinal and circumferential strain components (r = 0.78 and r = 0.71) but poor for radial strain (r = 0.30). Accordingly, agreement (bias ± 2SD) was -5 ± 6 % for longitudinal, -5 ± 7 % for circumferential, and 15 ± 19 % for radial strain. Intra-observer variability was low for all components (intra-class correlation coefficients (ICC) of respectively 0.89, 0.88 and 0.95) while inter-observer variability was higher, in particular for radial strain (ICC = 0.41). The present study shows that 3D strain analysis provided good estimates of circumferential and longitudinal strain, while estimates of radial strain were less accurate between observers.
Assuntos
Palavras-chave
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Função Ventricular Esquerda / Isquemia Miocárdica / Ecocardiografia Tridimensional / Ventrículos do Coração / Contração Miocárdica Tipo de estudo: Prognostic_studies Limite: Animals Idioma: En Revista: Int J Cardiovasc Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Bélgica
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Função Ventricular Esquerda / Isquemia Miocárdica / Ecocardiografia Tridimensional / Ventrículos do Coração / Contração Miocárdica Tipo de estudo: Prognostic_studies Limite: Animals Idioma: En Revista: Int J Cardiovasc Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Bélgica