Your browser doesn't support javascript.
loading
A new H2 (+) source: Conceptual study and experimental test of an upgraded version of the VIS-Versatile ion source.
Castro, G; Torrisi, G; Celona, L; Mascali, D; Neri, L; Sorbello, G; Leonardi, O; Patti, G; Castorina, G; Gammino, S.
Afiliação
  • Castro G; INFN-Laboratori Nazionali del Sud, Via S. Sofia 62, 95123 Catania, Italy.
  • Torrisi G; INFN-Laboratori Nazionali del Sud, Via S. Sofia 62, 95123 Catania, Italy.
  • Celona L; INFN-Laboratori Nazionali del Sud, Via S. Sofia 62, 95123 Catania, Italy.
  • Mascali D; INFN-Laboratori Nazionali del Sud, Via S. Sofia 62, 95123 Catania, Italy.
  • Neri L; INFN-Laboratori Nazionali del Sud, Via S. Sofia 62, 95123 Catania, Italy.
  • Sorbello G; INFN-Laboratori Nazionali del Sud, Via S. Sofia 62, 95123 Catania, Italy.
  • Leonardi O; INFN-Laboratori Nazionali del Sud, Via S. Sofia 62, 95123 Catania, Italy.
  • Patti G; INFN-Laboratori Nazionali del Sud, Via S. Sofia 62, 95123 Catania, Italy.
  • Castorina G; INFN-Laboratori Nazionali del Sud, Via S. Sofia 62, 95123 Catania, Italy.
  • Gammino S; INFN-Laboratori Nazionali del Sud, Via S. Sofia 62, 95123 Catania, Italy.
Rev Sci Instrum ; 87(8): 083303, 2016 Aug.
Article em En | MEDLINE | ID: mdl-27587109
ABSTRACT
The versatile ion source is an off-resonance microwave discharge ion source which produces a slightly overdense plasma at 2.45 GHz of pumping wave frequency extracting more than 60 mA proton beams and 50 mA He(+) beams. DAEδALUS and IsoDAR experiments require high intensities for H2 (+) beams to be accelerated by high power cyclotrons for neutrinos generation. In order to fulfill the new requirements, a new plasma chamber and injection system has been designed and manufactured for increasing the H2 (+) beam intensity. In this paper the studies for the increasing of the H2 (+)/p ratio and for the design of the new plasma chamber and injection system will be shown and discussed together with the experimental tests carried out at Istituto Nazionale di Fisica Nucleare-Laboratori Nazionali del Sud (INFN-LNS) and at Best Cyclotron Systems test-bench in Vancouver, Canada.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Itália
...