Your browser doesn't support javascript.
loading
Fast Megavoltage Computed Tomography: A Rapid Imaging Method for Total Body or Marrow Irradiation in Helical Tomotherapy.
Magome, Taiki; Haga, Akihiro; Takahashi, Yutaka; Nakagawa, Keiichi; Dusenbery, Kathryn E; Hui, Susanta K.
Afiliação
  • Magome T; Department of Radiological Sciences, Faculty of Health Sciences, Komazawa University, Tokyo, Japan; Department of Radiology, The University of Tokyo Hospital, Tokyo, Japan; Masonic Cancer Center, University of Minnesota, Minneapolis, Minnesota.
  • Haga A; Department of Radiology, The University of Tokyo Hospital, Tokyo, Japan.
  • Takahashi Y; Masonic Cancer Center, University of Minnesota, Minneapolis, Minnesota; Department of Radiation Oncology, Osaka University, Osaka, Japan.
  • Nakagawa K; Department of Radiology, The University of Tokyo Hospital, Tokyo, Japan.
  • Dusenbery KE; Department of Therapeutic Radiology, University of Minnesota, Minneapolis, Minnesota.
  • Hui SK; Masonic Cancer Center, University of Minnesota, Minneapolis, Minnesota; Department of Therapeutic Radiology, University of Minnesota, Minneapolis, Minnesota; Department of Radiation Oncology and Beckman Research Institute, City of Hope, Duarte, California. Electronic address: shui@coh.org.
Int J Radiat Oncol Biol Phys ; 96(3): 688-95, 2016 11 01.
Article em En | MEDLINE | ID: mdl-27681766
ABSTRACT

PURPOSE:

Megavoltage computed tomographic (MVCT) imaging has been widely used for the 3-dimensional (3-D) setup of patients treated with helical tomotherapy (HT). One drawback of MVCT is its very long imaging time, the result of slow couch speeds of approximately 1 mm/s, which can be difficult for the patient to tolerate. We sought to develop an MVCT imaging method allowing faster couch speeds and to assess its accuracy for image guidance for HT. METHODS AND MATERIALS Three cadavers were scanned 4 times with couch speeds of 1, 2, 3, and 4 mm/s. The resulting MVCT images were reconstructed using an iterative reconstruction (IR) algorithm with a penalty term of total variation and with a conventional filtered back projection (FBP) algorithm. The MVCT images were registered with kilovoltage CT images, and the registration errors from the 2 reconstruction algorithms were compared. This fast MVCT imaging was tested in 3 cases of total marrow irradiation as a clinical trial.

RESULTS:

The 3-D registration errors of the MVCT images reconstructed with the IR algorithm were smaller than the errors of images reconstructed with the FBP algorithm at fast couch speeds (2, 3, 4 mm/s). The scan time and imaging dose at a speed of 4 mm/s were reduced to 30% of those from a conventional coarse mode scan. For the patient imaging, faster MVCT (3 mm/s couch speed) scanning reduced the imaging time and still generated images useful for anatomic registration.

CONCLUSIONS:

Fast MVCT with the IR algorithm is clinically feasible for large 3-D target localization, which may reduce the overall time for the treatment procedure. This technique may also be useful for calculating daily dose distributions or organ motion analyses in HT treatment over a wide area. Automated integration of this imaging is at least needed to further assess its clinical benefits.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Medula Óssea / Tomografia Computadorizada por Raios X / Irradiação Corporal Total / Imagem Corporal Total / Radioterapia Guiada por Imagem Tipo de estudo: Diagnostic_studies / Guideline Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Int J Radiat Oncol Biol Phys Ano de publicação: 2016 Tipo de documento: Article País de publicação: EEUU / ESTADOS UNIDOS / ESTADOS UNIDOS DA AMERICA / EUA / UNITED STATES / UNITED STATES OF AMERICA / US / USA

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Medula Óssea / Tomografia Computadorizada por Raios X / Irradiação Corporal Total / Imagem Corporal Total / Radioterapia Guiada por Imagem Tipo de estudo: Diagnostic_studies / Guideline Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Int J Radiat Oncol Biol Phys Ano de publicação: 2016 Tipo de documento: Article País de publicação: EEUU / ESTADOS UNIDOS / ESTADOS UNIDOS DA AMERICA / EUA / UNITED STATES / UNITED STATES OF AMERICA / US / USA