Your browser doesn't support javascript.
loading
Single-source chest-abdomen-pelvis cancer staging on a third generation dual-source CT system: comparison of automated tube potential selection to second generation dual-source CT.
Park, Clara; Gruber-Rouh, Tatjana; Leithner, Doris; Zierden, Amelie; Albrecht, Mortiz H; Wichmann, Julian L; Bodelle, Boris; Elsabaie, Mohamed; Scholtz, Jan-Erik; Kaup, Moritz; Vogl, Thomas J; Beeres, Martin.
Afiliação
  • Park C; Department of Diagnostic and Interventional Radiology, Clinic of the Goethe University, Haus 23C UG, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany.
  • Gruber-Rouh T; Department of Diagnostic and Interventional Radiology, Clinic of the Goethe University, Haus 23C UG, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany.
  • Leithner D; Department of Diagnostic and Interventional Radiology, Clinic of the Goethe University, Haus 23C UG, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany.
  • Zierden A; Department of Diagnostic and Interventional Radiology, Clinic of the Goethe University, Haus 23C UG, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany.
  • Albrecht MH; Department of Diagnostic and Interventional Radiology, Clinic of the Goethe University, Haus 23C UG, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany.
  • Wichmann JL; Department of Diagnostic and Interventional Radiology, Clinic of the Goethe University, Haus 23C UG, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany.
  • Bodelle B; Department of Diagnostic and Interventional Radiology, Clinic of the Goethe University, Haus 23C UG, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany.
  • Elsabaie M; Department of Diagnostic and Interventional Radiology, Clinic of the Goethe University, Haus 23C UG, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany.
  • Scholtz JE; Department of Diagnostic and Interventional Radiology, Clinic of the Goethe University, Haus 23C UG, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany.
  • Kaup M; Department of Diagnostic and Interventional Radiology, Clinic of the Goethe University, Haus 23C UG, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany.
  • Vogl TJ; Department of Diagnostic and Interventional Radiology, Clinic of the Goethe University, Haus 23C UG, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany.
  • Beeres M; Department of Diagnostic and Interventional Radiology, Clinic of the Goethe University, Haus 23C UG, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany. beeres@gmx.net.
Cancer Imaging ; 16(1): 33, 2016 Oct 10.
Article em En | MEDLINE | ID: mdl-27724954
ABSTRACT

BACKGROUND:

Evaluation of latest generation automated attenuation-based tube potential selection (ATPS) impact on image quality and radiation dose in contrast-enhanced chest-abdomen-pelvis computed tomography examinations for gynaecologic cancer staging.

METHODS:

This IRB approved single-centre, observer-blinded retrospective study with a waiver for informed consent included a total of 100 patients with contrast-enhanced chest-abdomen-pelvis CT for gynaecologic cancer staging. All patients were examined with activated ATPS for adaption of tube voltage to body habitus. 50 patients were scanned on a third-generation dual-source CT (DSCT), and another 50 patients on a second-generation DSCT. Predefined image quality setting remained stable between both groups at 120 kV and a current of 210 Reference mAs. Subjective image quality assessment was performed by two blinded readers independently. Attenuation and image noise were measured in several anatomic structures. Signal-to-noise ratio (SNR) was calculated. For the evaluation of radiation exposure, CT dose index (CTDIvol) values were compared.

RESULTS:

Diagnostic image quality was obtained in all patients. The median CTDIvol (6.1 mGy, range 3.9-22 mGy) was 40 % lower when using the algorithm compared with the previous ATCM protocol (median 10.2 mGy · cm, range 5.8-22.8 mGy). A reduction in potential to 90 kV occurred in 19 cases, a reduction to 100 kV in 23 patients and a reduction to 110 kV in 3 patients of our experimental cohort. These patients received significantly lower radiation exposure compared to the former used protocol.

CONCLUSION:

Latest generation automated ATPS on third-generation DSCT provides good diagnostic image quality in chest-abdomen-pelvis CT while average radiation dose is reduced by 40 % compared to former ATPS protocol on second-generation DSCT.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pelve / Tomografia Computadorizada por Raios X / Abdome / Neoplasias dos Genitais Femininos Tipo de estudo: Evaluation_studies / Guideline / Observational_studies Limite: Adult / Aged / Aged80 / Female / Humans / Middle aged Idioma: En Revista: Cancer Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM / NEOPLASIAS Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pelve / Tomografia Computadorizada por Raios X / Abdome / Neoplasias dos Genitais Femininos Tipo de estudo: Evaluation_studies / Guideline / Observational_studies Limite: Adult / Aged / Aged80 / Female / Humans / Middle aged Idioma: En Revista: Cancer Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM / NEOPLASIAS Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Alemanha