Your browser doesn't support javascript.
loading
Clinical outcomes of Ahmed glaucoma valve in anterior chamber versus ciliary sulcus.
Bayer, A; Önol, M.
Afiliação
  • Bayer A; Dünyagöz Ankara Hospital, Glaucoma Department, Ankara, Turkey.
  • Önol M; Dünyagöz Ankara Hospital, Glaucoma Department, Ankara, Turkey.
Eye (Lond) ; 31(4): 608-614, 2017 Apr.
Article em En | MEDLINE | ID: mdl-27983734
ABSTRACT
PurposeTo evaluate the outcomes of Ahmed glaucoma valve (AGV) tube insertion through the anterior chamber angle (ACA) or through the ciliary sulcus (CS).Patients and methodsIn this case-control study, we retrospectively reviewed the charts of consecutive glaucoma patients who had undergone AGV implantation either through the ACA or the CS between March 2009 and December 2014. The main outcome measures were intraocular pressure (IOP), number of glaucoma medications prescribed, best corrected visual acuity (BCVA), glaucoma type, success rate, complications, and survival ratios. Statistical analysis was carried out using SPSS.ResultsThere were 68 eyes in the ACA group and 35 eyes in the CS group. There were no significant differences between the groups for age, sex, laterality, IOP, preoperative glaucoma medication number, BCVA or glaucoma type (P>0.05). The postoperative follow-up period was 27.2±16.5 months and 30.2±17.7 months for the ACA and the CS groups (P=0.28); IOP values were significantly reduced at the last visit to 16.4±7.2 mm Hg and 14.4±6.8 mm Hg. The difference in the last-visit IOP between the groups was not significant (P=0.06), but the IOP reduction ratio was higher in the CS group (P=0.03). There was no significant difference in the number of postoperative medications (P=0.18). Postoperative complications were similar, but the incidence of flat anterior chamber was higher in the ACA group (P=0.05).ConclusionsThe use of an AGV can control IOP in the majority of cases whether placed in the ACA or the CS. The IOP reduction ratio seemed to be higher in the CS group.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Glaucoma / Corpo Ciliar / Implantação de Prótese / Implantes para Drenagem de Glaucoma / Câmara Anterior Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male / Middle aged País/Região como assunto: Asia Idioma: En Revista: Eye (Lond) Assunto da revista: OFTALMOLOGIA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Turquia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Glaucoma / Corpo Ciliar / Implantação de Prótese / Implantes para Drenagem de Glaucoma / Câmara Anterior Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male / Middle aged País/Região como assunto: Asia Idioma: En Revista: Eye (Lond) Assunto da revista: OFTALMOLOGIA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Turquia