Isotopic separation of acetaldehyde and methanol from their deuterated isotopologues on a porous layer open tubular column allows quantification by stable isotope dilution without mass spectrometric detection.
Schmarr, Hans-Georg; Wacker, Michael; Mathes, Maximilian.
Afiliação
  • Schmarr HG; Dienstleistungszentrum Ländlicher Raum (DLR) Rheinpfalz, Institute for Viticulture and Oenology, Breitenweg 71, 67435 Neustadt an der Weinstraße, Germany; University Duisburg-Essen, Faculty for Chemistry, Instrumental Analytical Chemistry, Universitätsstraße 5, 45141 Essen, Germany. Electronic address: hans-georg.schmarr@dlr.rlp.de.
  • Wacker M; Dienstleistungszentrum Ländlicher Raum (DLR) Rheinpfalz, Institute for Viticulture and Oenology, Breitenweg 71, 67435 Neustadt an der Weinstraße, Germany.
  • Mathes M; Dienstleistungszentrum Ländlicher Raum (DLR) Rheinpfalz, Institute for Viticulture and Oenology, Breitenweg 71, 67435 Neustadt an der Weinstraße, Germany.
J Chromatogr A ; 1481: 111-115, 2017 Jan 20.
Article em En | MEDLINE | ID: mdl-28012586
An isotopic separation of acetaldehyde and acetaldehyde-2,2,2-d3 was achieved in a temperature programmed run on a porous layer open tubular (PLOT) capillary column coated with particles of divinylbenzene ethylene glycol/dimethylacrylate (Rt®-U-BOND). This is the prerequisite for the development of quantitative analytical methods based on a stable isotope dilution assay (SIDA) without a mass spectrometric detection (non-MS SIDA). For routine analysis a flame ionization detector (FID) can thus be applied as a robust and low-cost alternative. In a preliminary study, static headspace extraction and gas chromatographic separation (HS-GC-FID) of acetaldehyde in aqueous solutions was shown as an application. Good linearity was obtained in a calibration range from 0.4 to 40mgL-1, with peak integration benefitting from the inverse isotope effect encountered on the specific porous polymer. Furthermore, separation of methanol and deuterated methanol (d3) could also be achieved under the same chromatographic conditions. The achieved isotopic separation of these important volatile compounds now allows non-MS SIDA-based methods that are still to be developed.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Massas / Técnicas de Diluição do Indicador / Deutério / Metanol / Marcação por Isótopo / Acetaldeído Tipo de estudo: Diagnostic_studies Idioma: En Revista: J Chromatogr A Ano de publicação: 2017 Tipo de documento: Article País de publicação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Massas / Técnicas de Diluição do Indicador / Deutério / Metanol / Marcação por Isótopo / Acetaldeído Tipo de estudo: Diagnostic_studies Idioma: En Revista: J Chromatogr A Ano de publicação: 2017 Tipo de documento: Article País de publicação: Holanda