Hand Surgery and Fluoroscopic Eye Radiation Dosage: A Prospective Pilot Comparison of Large Versus Mini C-Arm Fluoroscopy Use.
Wang, Mark L; Hoffler, C Edward; Ilyas, Asif M; Kirkpatrick, William H; Beredjiklian, Pedro K; Leinberry, Charles F.
Afiliação
  • Wang ML; Thomas Jefferson University, Philadelphia, PA, USA.
  • Hoffler CE; Thomas Jefferson University, Philadelphia, PA, USA.
  • Ilyas AM; Thomas Jefferson University, Philadelphia, PA, USA.
  • Kirkpatrick WH; Thomas Jefferson University, Philadelphia, PA, USA.
  • Beredjiklian PK; Thomas Jefferson University, Philadelphia, PA, USA.
  • Leinberry CF; Thomas Jefferson University, Philadelphia, PA, USA.
Hand (N Y) ; 12(1): 21-25, 2017 01.
Article em En | MEDLINE | ID: mdl-28082838
ABSTRACT

Background:

The purpose of this study is to (1) perform a prospective pilot comparison of the impact of large versus mini C-arm fluoroscopy on resultant eye radiation exposure and (2) test the hypothesis that the use of either modality during routine hand surgery does not exceed the current recommended limits to critical eye radiation dosage.

Methods:

Over a 12-month period, eye radiation exposure was prospectively measured by a board-certified hand surgeon using both large and mini C-arm fluoroscopy. For each modality, accumulated eye radiation dosage was measured monthly, while fluoroscopic radiation output was recorded, including total exposure time and dose rate.

Results:

A total of 58 cases were recorded using large C-arm and 25 cases using mini C-arm. Between the 2 groups, there was not a significant difference with total exposure time (P = .88) and average dose rate per case (P = .10). With the use of either modality, average monthly eye radiation exposure fell within the undetectable range (<30 mrem), significantly less than the current recommended limit of critical eye radiation (167 mrem/month).

Conclusions:

The impact of various fluoroscopic sources on eye radiation exposure remains relatively unexplored. In this study, the minimal detectable eye radiation dosages observed in both groups were reliably consistent. Our findings suggest that accumulated eye radiation dosage, from the use of either fluoroscopic modality, does not approach previously reported levels of critical radiation loads.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fluoroscopia / Exposição Ocupacional / Exposição à Radiação / Olho / Cirurgiões / Mãos Tipo de estudo: Observational_studies Limite: Humans Idioma: En Revista: Hand (N Y) Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fluoroscopia / Exposição Ocupacional / Exposição à Radiação / Olho / Cirurgiões / Mãos Tipo de estudo: Observational_studies Limite: Humans Idioma: En Revista: Hand (N Y) Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Estados Unidos