Measurements of intermediate-frequency electric and magnetic fields in households.
Aerts, Sam; Calderon, Carolina; Valic, Blaz; Maslanyj, Myron; Addison, Darren; Mee, Terry; Goiceanu, Cristian; Verloock, Leen; Van den Bossche, Matthias; Gajsek, Peter; Vermeulen, Roel; Röösli, Martin; Cardis, Elisabeth; Martens, Luc; Joseph, Wout.
Afiliação
  • Aerts S; Department of Information Technology, Ghent University/iMinds, iGent, Technologiepark-Zwijnaarde 15, B-9052 Ghent, Belgium. Electronic address: sam.aerts@intec.ugent.be.
  • Calderon C; Centre for Radiation, Chemical and Environmental Hazards, Public Health England, Chilton, Didcot, Oxon OX11 0RQ, United Kingdom.
  • Valic B; Institute of Non-Ionizing Radiation (INIS), Pohorskega bataljona 215, Ljubljana 1000, Slovenia.
  • Maslanyj M; Centre for Radiation, Chemical and Environmental Hazards, Public Health England, Chilton, Didcot, Oxon OX11 0RQ, United Kingdom.
  • Addison D; Centre for Radiation, Chemical and Environmental Hazards, Public Health England, Chilton, Didcot, Oxon OX11 0RQ, United Kingdom.
  • Mee T; Centre for Radiation, Chemical and Environmental Hazards, Public Health England, Chilton, Didcot, Oxon OX11 0RQ, United Kingdom.
  • Goiceanu C; Centre for Radiation, Chemical and Environmental Hazards, Public Health England, Chilton, Didcot, Oxon OX11 0RQ, United Kingdom.
  • Verloock L; Department of Information Technology, Ghent University/iMinds, iGent, Technologiepark-Zwijnaarde 15, B-9052 Ghent, Belgium.
  • Van den Bossche M; Department of Information Technology, Ghent University/iMinds, iGent, Technologiepark-Zwijnaarde 15, B-9052 Ghent, Belgium.
  • Gajsek P; Institute of Non-Ionizing Radiation (INIS), Pohorskega bataljona 215, Ljubljana 1000, Slovenia.
  • Vermeulen R; Institute for Risk Assessment Sciences, Department of Environmental Epidemiology, Utrecht University, Yalelaan 2, 3508 Utrecht, The Netherlands.
  • Röösli M; Swiss Tropical and Public Health Institute (Swiss TPH), Socinstrasse 57, P.O. Box, 4002 Basel, Switzerland; University of Basel, Petersplatz 1, 4003 Basel, Switzerland.
  • Cardis E; Barcelona Institute for Global Health (ISGlobal) and Municipal Institute of Medical Research (IMIM-Hospital del Mar), Doctor Aiguader, 88, 08003 Barcelona, Spain.
  • Martens L; Department of Information Technology, Ghent University/iMinds, iGent, Technologiepark-Zwijnaarde 15, B-9052 Ghent, Belgium.
  • Joseph W; Department of Information Technology, Ghent University/iMinds, iGent, Technologiepark-Zwijnaarde 15, B-9052 Ghent, Belgium.
Environ Res ; 154: 160-170, 2017 04.
Article em En | MEDLINE | ID: mdl-28086101
Historically, assessment of human exposure to electric and magnetic fields has focused on the extremely-low-frequency (ELF) and radiofrequency (RF) ranges. However, research on the typically emitted fields in the intermediate-frequency (IF) range (300Hz to 1MHz) as well as potential effects of IF fields on the human body remains limited, although the range of household appliances with electrical components working in the IF range has grown significantly (e.g., induction cookers and compact fluorescent lighting). In this study, an extensive measurement survey was performed on the levels of electric and magnetic fields in the IF range typically present in residences as well as emitted by a wide range of household appliances under real-life circumstances. Using spot measurements, residential IF field levels were found to be generally low, while the use of certain appliances at close distance (20cm) may result in a relatively high exposure. Overall, appliance emissions contained either harmonic signals, with fundamental frequencies between 6kHz and 300kHz, which were sometimes accompanied by regions in the IF spectrum of rather noisy, elevated field strengths, or much more capricious spectra, dominated by 50Hz harmonics emanating far in the IF domain. The maximum peak field strengths recorded at 20cm were 41.5V/m and 2.7A/m, both from induction cookers. Finally, none of the appliance emissions in the IF range exceeded the exposure summation rules recommended by the International Commission on Non-Ionizing Radiation Protection guidelines and the International Electrotechnical Commission (IEC 62233) standard at 20cm and beyond (maximum exposure quotients EQE 1.0 and EQH 0.13).
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Iluminação / Campos Eletromagnéticos / Exposição Ambiental / Campos Magnéticos / Habitação Tipo de estudo: Qualitative_research Aspecto: Determinantes_sociais_saude Limite: Humans País/Região como assunto: Europa Idioma: En Revista: Environ Res Ano de publicação: 2017 Tipo de documento: Article País de publicação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Iluminação / Campos Eletromagnéticos / Exposição Ambiental / Campos Magnéticos / Habitação Tipo de estudo: Qualitative_research Aspecto: Determinantes_sociais_saude Limite: Humans País/Região como assunto: Europa Idioma: En Revista: Environ Res Ano de publicação: 2017 Tipo de documento: Article País de publicação: Holanda