Your browser doesn't support javascript.
loading
Control and automation of multilayered integrated microfluidic device fabrication.
Kipper, Sarit; Frolov, Ludmila; Guy, Ortal; Pellach, Michal; Glick, Yair; Malichi, Asaf; Knisbacher, Binyamin A; Barbiro-Michaely, Efrat; Avrahami, Dorit; Yavets-Chen, Yehuda; Levanon, Erez Y; Gerber, Doron.
Afiliação
  • Kipper S; Mina and Everard Goodman Faculty of Life Sciences, Bar-Ilan Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan, Israel. doron.gerber@biu.ac.il.
  • Frolov L; Mina and Everard Goodman Faculty of Life Sciences, Bar-Ilan Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan, Israel. doron.gerber@biu.ac.il.
  • Guy O; Mina and Everard Goodman Faculty of Life Sciences, Bar-Ilan Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan, Israel. doron.gerber@biu.ac.il.
  • Pellach M; Mina and Everard Goodman Faculty of Life Sciences, Bar-Ilan Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan, Israel. doron.gerber@biu.ac.il.
  • Glick Y; Mina and Everard Goodman Faculty of Life Sciences, Bar-Ilan Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan, Israel. doron.gerber@biu.ac.il.
  • Malichi A; Mina and Everard Goodman Faculty of Life Sciences, Bar-Ilan Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan, Israel. doron.gerber@biu.ac.il.
  • Knisbacher BA; Mina and Everard Goodman Faculty of Life Sciences, Bar-Ilan Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan, Israel. doron.gerber@biu.ac.il.
  • Barbiro-Michaely E; Mina and Everard Goodman Faculty of Life Sciences, Bar-Ilan Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan, Israel. doron.gerber@biu.ac.il.
  • Avrahami D; Mina and Everard Goodman Faculty of Life Sciences, Bar-Ilan Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan, Israel. doron.gerber@biu.ac.il.
  • Yavets-Chen Y; Mina and Everard Goodman Faculty of Life Sciences, Bar-Ilan Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan, Israel. doron.gerber@biu.ac.il.
  • Levanon EY; Mina and Everard Goodman Faculty of Life Sciences, Bar-Ilan Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan, Israel. doron.gerber@biu.ac.il.
  • Gerber D; Mina and Everard Goodman Faculty of Life Sciences, Bar-Ilan Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan, Israel. doron.gerber@biu.ac.il.
Lab Chip ; 17(3): 557-566, 2017 01 31.
Article em En | MEDLINE | ID: mdl-28102868
ABSTRACT
Integrated microfluidics is a sophisticated three-dimensional (multi layer) solution for high complexity serial or parallel processes. Fabrication of integrated microfluidic devices requires soft lithography and the stacking of thin-patterned PDMS layers. Precise layer alignment and bonding is crucial. There are no previously reported standards for alignment of the layers, which is mostly performed using uncontrolled processes with very low alignment success. As a result, integrated microfluidics is mostly used in academia rather than in the many potential industrial applications. We have designed and manufactured a semiautomatic Microfluidic Device Assembly System (µDAS) for full device production. µDAS comprises an electrooptic mechanical system consisting of four main parts optical system, smart media holder (for PDMS), a micropositioning xyzθ system and a macropositioning XY mechanism. The use of the µDAS yielded valuable information regarding PDMS as the material for device fabrication, revealed previously unidentified errors, and enabled optimization of a robust fabrication process. In addition, we have demonstrated the utilization of the µDAS technology for fabrication of a complex 3 layered device with over 12 000 micromechanical valves and an array of 64 × 64 DNA spots on a glass substrate with high yield and high accuracy. We increased fabrication yield from 25% to about 85% with an average layer alignment error of just ∼4 µm. It also increased our protein expression yields from 80% to over 90%, allowing us to investigate more proteins per experiment. The µDAS has great potential to become a valuable tool for both advancing integrated microfluidics in academia and producing and applying microfluidic devices in the industry.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Automação / Técnicas Analíticas Microfluídicas / Desenho de Equipamento / Dispositivos Lab-On-A-Chip Idioma: En Revista: Lab Chip Assunto da revista: BIOTECNOLOGIA / QUIMICA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Israel

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Automação / Técnicas Analíticas Microfluídicas / Desenho de Equipamento / Dispositivos Lab-On-A-Chip Idioma: En Revista: Lab Chip Assunto da revista: BIOTECNOLOGIA / QUIMICA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Israel