Simplified method for creating a density-absorbed dose calibration curve for the low dose range from Gafchromic EBT3 film.
Gotanda, Tatsuhiro; Katsuda, Toshizo; Gotanda, Rumi; Kuwano, Tadao; Akagawa, Takuya; Tanki, Nobuyoshi; Tabuchi, Akihiko; Shimono, Tetsunori; Kawaji, Yasuyuki.
Afiliação
  • Gotanda T; Department of Radiological Science, Faculty of Health Sciences, Junshin Gakuen University, Fukuoka, Japan.
  • Katsuda T; Department of Radiological Technology, Faculty of Health Sciences, Butsuryo College of Osaka, Osaka, Japan.
  • Gotanda R; Department of Radiological Sciences, Ibaraki Prefectural University of Health Sciences, Ibaraki, Japan.
  • Kuwano T; Department of Radiological Technology, Graduate School of Health Sciences, Okayama University, Okayama, Japan.
  • Akagawa T; Department of Radiological Technology, Tokushima Red Cross Hospital, Tokushima, Japan.
  • Tanki N; Department of Radiological Technology, Faculty of Health Sciences, Butsuryo College of Osaka, Osaka, Japan.
  • Tabuchi A; Department of Radiology, Kawasaki Medical School Kawasaki Hospital, Okayama, Japan.
  • Shimono T; Department of Radiological Science, Faculty of Health Sciences, Junshin Gakuen University, Fukuoka, Japan.
  • Kawaji Y; Department of Radiological Science, Faculty of Health Sciences, Junshin Gakuen University, Fukuoka, Japan.
J Med Phys ; 41(4): 266-270, 2016.
Article em En | MEDLINE | ID: mdl-28144120
Radiochromic film dosimeters have a disadvantage in comparison with an ionization chamber in that the dosimetry process is time-consuming for creating a density-absorbed dose calibration curve. The purpose of this study was the development of a simplified method of creating a density-absorbed dose calibration curve from radiochromic film within a short time. This simplified method was performed using Gafchromic EBT3 film with a low energy dependence and step-shaped Al filter. The simplified method was compared with the standard method. The density-absorbed dose calibration curves created using the simplified and standard methods exhibited approximately similar straight lines, and the gradients of the density-absorbed dose calibration curves were -32.336 and -33.746, respectively. The simplified method can obtain calibration curves within a much shorter time compared to the standard method. It is considered that the simplified method for EBT3 film offers a more time-efficient means of determining the density-absorbed dose calibration curve within a low absorbed dose range such as the diagnostic range.