Your browser doesn't support javascript.
loading
Comparison of cobas 4800, m2000, Viper XTR, and Infinity 80 Automated Instruments When Processing Urine Specimens for the Diagnosis of Chlamydia trachomatis and Neisseria gonorrhoeae.
Chernesky, Max A; Jang, Dan; Gilchrist, Jodi; Smieja, Marek; Arias, Manuel; Hatchette, Todd; Poirier, Andre; Mayne, Donna; Ratnam, Sam.
Afiliação
  • Chernesky MA; From the *Pathology & Molecular Medicine, St. Joseph's Healthcare/McMaster University, Hamilton, ON; †Queen Elizabeth II Health Sciences Centre, Dalhousie University, Halifax, NS; ‡Trois-Rivières Regional Hospital, Trois-Rivières, QC, Canada; §Sacred Heart Hospital, Pensacola, FL; and ¶Newfoundland & Labrador Public Health Laboratory, St. John's, NL, Canada.
Sex Transm Dis ; 44(3): 161-165, 2017 03.
Article em En | MEDLINE | ID: mdl-28182591
OBJECTIVES: North American and European advisory groups recommend testing for Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG) with nucleic acid amplification tests. Testing is often performed on automated instruments. The objectives of this study were to process urines for the diagnosis of CT and NG and to examine workflow procedures and outcomes. METHODS: While processing 1, 24, 48, 96, and 192 urine specimens on 3 batch-mode systems which use 96-well plates: cobas 4800, m2000, and Viper XTR and the random access cartridge testing GeneXpert Infinity 80, we measured assay performance, hands-on time for processing and maintenance, reagents and plastics consumption, time required to obtain results, and testing accuracy. RESULTS: The Infinity 80 required the least hands-on time for single specimens and smaller batches, whereas the Viper XTR and m2000 required the most hands-on time for all batch sizes. Cumulative daily, weekly, and monthly maintenance was highest for the Viper XTR and lowest for Infinity 80. All batch-mode instruments consumed large amounts of disposables. Time to results was shortest for the Infinity 80, and the Viper XTR provided the shortest time for the batch-mode instruments. All systems showed similar diagnostic accuracy. CONCLUSIONS: Because detection performances were similar, issues of hands-on time, maintenance, time to results, and consumables are important operational factors for the diagnosis and treatment of CT/NG infections.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Avaliação de Processos e Resultados em Cuidados de Saúde / Manejo de Espécimes / Infecções por Chlamydia / Gonorreia / Urinálise / Técnicas de Amplificação de Ácido Nucleico Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Sex Transm Dis Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Canadá País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Avaliação de Processos e Resultados em Cuidados de Saúde / Manejo de Espécimes / Infecções por Chlamydia / Gonorreia / Urinálise / Técnicas de Amplificação de Ácido Nucleico Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Sex Transm Dis Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Canadá País de publicação: Estados Unidos