Your browser doesn't support javascript.
loading
Increasing the linear dynamic range in LC-MS: is it valid to use a less abundant isotopologue?
Trobbiani, Stephen; Stockham, Peter; Scott, Timothy.
Afiliação
  • Trobbiani S; Forensic Science SA, GPO Box 2790, Adelaide, South Australia, 5000, Australia.
  • Stockham P; Forensic Science SA, GPO Box 2790, Adelaide, South Australia, 5000, Australia.
  • Scott T; Flinders University, Sturt Road, Bedford Park, South Australia, 5042, Australia.
Drug Test Anal ; 9(10): 1630-1636, 2017 Oct.
Article em En | MEDLINE | ID: mdl-28207195
ABSTRACT
Liquid chromatography-mass spectrometry (LC-MS) has quickly become the analytical method of choice in forensic toxicology laboratories due to its ability to detect a very wide range of compounds in a single analysis. One of the major limitations of LC-MS however, is a relatively limited linear dynamic range for quantitation. A new approach to combating this problem is to use the [+1 M + H]+ isotope mass peak for quantitation, thereby reducing saturation at the detector and extending the linear range. This is particularly useful in full-scan applications, such as quadrupole-time-of-flight (QTOF) mass spectrometry, where the isotopic mass peaks are acquired as a matter of course. Due to the variation in abundance of naturally occurring isotopes for common elements, especially 13 C, this technique has the potential to lead to additional quantitative error. Through a review of published isotope ratio mass spectrometry data, we have assessed this potential for error and found that it is likely to be less than 2% and unlikely to be more than 4%, although this may not apply to compounds containing high numbers of nitrogen or sulphur atoms. This additional potential error must be considered before using this technique as it may not be appropriate for all applications. We have deemed it fit for purpose for our application and demonstrate the applicability of this technique to a quantitative LC-TOF method. © 2017 Commonwealth of Australia. Drug Testing and Analysis © 2017 John Wiley & Sons, Ltd.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Massas / Preparações Farmacêuticas / Detecção do Abuso de Substâncias / Cromatografia Líquida Limite: Humans Idioma: En Revista: Drug Test Anal Assunto da revista: FARMACOLOGIA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Austrália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Massas / Preparações Farmacêuticas / Detecção do Abuso de Substâncias / Cromatografia Líquida Limite: Humans Idioma: En Revista: Drug Test Anal Assunto da revista: FARMACOLOGIA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Austrália