Your browser doesn't support javascript.
loading
Impact of denoising on precision and accuracy of saturation-recovery-based myocardial T1 mapping.
Bustin, Aurélien; Ferry, Pauline; Codreanu, Andrei; Beaumont, Marine; Liu, Shufang; Burschka, Darius; Felblinger, Jacques; Brau, Anja C S; Menini, Anne; Odille, Freddy.
Afiliação
  • Bustin A; GE Global Research, Munich, Germany.
  • Ferry P; Department of Computer Science, Technische Universität München, Munich, Germany.
  • Codreanu A; Imagerie Adaptative Diagnostique et Interventionnelle, INSERM U947 et Université de Lorraine, Nancy, France.
  • Beaumont M; Imagerie Adaptative Diagnostique et Interventionnelle, INSERM U947 et Université de Lorraine, Nancy, France.
  • Liu S; Service de Cardiologie, Centre Hospitalier de Luxembourg, Luxembourg.
  • Burschka D; Imagerie Adaptative Diagnostique et Interventionnelle, INSERM U947 et Université de Lorraine, Nancy, France.
  • Felblinger J; CIC-IT 1433, INSERM, Université de Lorraine, CHRU de Nancy, Nancy, France.
  • Brau ACS; GE Global Research, Munich, Germany.
  • Menini A; Department of Computer Science, Technische Universität München, Munich, Germany.
  • Odille F; Department of Computer Science, Technische Universität München, Munich, Germany.
J Magn Reson Imaging ; 46(5): 1377-1388, 2017 11.
Article em En | MEDLINE | ID: mdl-28376285
PURPOSE: To evaluate the impact of a novel postprocessing denoising technique on accuracy and precision in myocardial T1 mapping. MATERIALS AND METHODS: This study introduces a fast and robust denoising method developed for magnetic resonance T1 mapping. The technique imposes edge-preserving regularity and exploits the co-occurence of spatial gradients in the acquired T1 -weighted images. The proposed approach was assessed in simulations, ex vivo data and in vivo imaging on a cohort of 16 healthy volunteers (12 males, average age 39 ± 8 years, 62 ± 9 bpm) both in pre- and postcontrast injection. The method was evaluated in myocardial T1 mapping at 3T with a saturation-recovery technique that is accurate but sensitive to noise. ROIs in the myocardium and left-ventricle blood pool were analyzed by an experienced reader. Mean T1 values and standard deviation were extracted and compared in all studies. RESULTS: Simulations on synthetic phantom showed signal-to-noise ratio and sharpness improvement with the proposed method in comparison with conventional denoising. In vivo results demonstrated that our method preserves accuracy, as no difference in mean T1 values was observed in the myocardium (precontrast: 1433/1426 msec, 95%CI: [-40.7, 55.9], p = 0.75, postcontrast: 766/759 msec, 95%CI: [-60.7, 77.2], p = 0.8). Meanwhile, precision was improved with standard deviations of T1 values being significantly decreased (precontrast: 223/151 msec, 95%CI: [27.3, 116.5], p = 0.003, postcontrast: 176/135 msec, 95%CI: [5.5, 77.1], p = 0.03). CONCLUSION: The proposed denoising method preserves accuracy and improves precision in myocardial T1 mapping, with the potential to offer better map visualization and analysis. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2017;46:1377-1388.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Coração / Miocárdio Tipo de estudo: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: J Magn Reson Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Alemanha País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Coração / Miocárdio Tipo de estudo: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: J Magn Reson Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Alemanha País de publicação: Estados Unidos