Your browser doesn't support javascript.
loading
Large field of view, fast and low dose multimodal phase-contrast imaging at high x-ray energy.
Astolfo, Alberto; Endrizzi, Marco; Vittoria, Fabio A; Diemoz, Paul C; Price, Benjamin; Haig, Ian; Olivo, Alessandro.
Afiliação
  • Astolfo A; Department of Medical Physics and Biomedical Engineering, University College London, Malet Place, Gower Street, London, United Kingdom. a.astolfo@ucl.ac.uk.
  • Endrizzi M; Department of Medical Physics and Biomedical Engineering, University College London, Malet Place, Gower Street, London, United Kingdom.
  • Vittoria FA; Department of Medical Physics and Biomedical Engineering, University College London, Malet Place, Gower Street, London, United Kingdom.
  • Diemoz PC; Department of Medical Physics and Biomedical Engineering, University College London, Malet Place, Gower Street, London, United Kingdom.
  • Price B; X-Tek Systems-Nikon, Tring Business Centre, Icknield Way, Tring, Hertfordshire, UK.
  • Haig I; X-Tek Systems-Nikon, Tring Business Centre, Icknield Way, Tring, Hertfordshire, UK.
  • Olivo A; Department of Medical Physics and Biomedical Engineering, University College London, Malet Place, Gower Street, London, United Kingdom. a.olivo@ucl.ac.uk.
Sci Rep ; 7(1): 2187, 2017 05 19.
Article em En | MEDLINE | ID: mdl-28526835
ABSTRACT
X-ray phase contrast imaging (XPCI) is an innovative imaging technique which extends the contrast capabilities of 'conventional' absorption based x-ray systems. However, so far all XPCI implementations have suffered from one or more of the following

limitations:

low x-ray energies, small field of view (FOV) and long acquisition times. Those limitations relegated XPCI to a 'research-only' technique with an uncertain future in terms of large scale, high impact applications. We recently succeeded in designing, realizing and testing an XPCI system, which achieves significant steps toward simultaneously overcoming these limitations. Our system combines, for the first time, large FOV, high energy and fast scanning. Importantly, it is capable of providing high image quality at low x-ray doses, compatible with or even below those currently used in medical imaging. This extends the use of XPCI to areas which were unpractical or even inaccessible to previous XPCI solutions. We expect this will enable a long overdue translation into application fields such as security screening, industrial inspections and large FOV medical radiography - all with the inherent advantages of the XPCI multimodality.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Sci Rep Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Sci Rep Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Reino Unido