Temperature changes of one-piece implants during the setting of acrylic resin temporary crown. The effect of implant diameter. An in vitro study.
Slutzkey, S; Cohen, O; Lauritano, D; Moses, O; Ormianer, Z; Tal, H; Kolerman, R; Carinci, F; Matalon, S.
Afiliação
  • Slutzkey S; Department of Periodontology and Oral Implantology, School of Dental Medicine, Tel-Aviv University, Tel-Aviv, Israel.
  • Cohen O; Department of Periodontology and Oral Implantology, School of Dental Medicine, Tel-Aviv University, Tel-Aviv, Israel.
  • Lauritano D; Department of Medicine and Surgery, University of Milan-Bicocca, Monza, Italy.
  • Moses O; Department of Periodontology and Oral Implantology, School of Dental Medicine, Tel-Aviv University, Tel-Aviv, Israel.
  • Ormianer Z; Department of Oral Rehabilitation, School of Dental Medicine, Tel-Aviv University, Tel-Aviv, Israel.
  • Tal H; Department of Periodontology and Oral Implantology, School of Dental Medicine, Tel-Aviv University, Tel-Aviv, Israel.
  • Kolerman R; Department of Periodontology and Oral Implantology, School of Dental Medicine, Tel-Aviv University, Tel-Aviv, Israel.
  • Carinci F; Department of Morphology, Surgery and Experimental Medicine, University of Ferrara, Ferrara, Italy.
  • Matalon S; Department of Oral Rehabilitation, School of Dental Medicine, Tel-Aviv University, Tel-Aviv, Israel.
J Biol Regul Homeost Agents ; 31(2 Suppl 1): 53-60, 2017.
Article em En | MEDLINE | ID: mdl-28691454
ABSTRACT
The purpose of this work is to evaluate changes in temperature of one-piece titanium implant surface during the setting of acrylic resin temporary crowns and to correlate thermal changes to implant diameter. Thirty-three one-piece implants (ARRP, Alpha-Biotec) were divided into 3 groups according to diameter size (G1=3 mm, G2=3.3 mm, G3=3.6 mm). Implants were mounted on an acrylic glass apparatus. Thermocouples were positioned at the most coronal thread. Lower incisor temporary polycarbonate crowns were filled with 80 µL of self-curing acrylic resin and positioned immediately on the implant abutment. Thermal changes of the implant surface were recorded continuously for 10 min. Data were statistically analyzed using one-way analysis of variance. The mean initial temperature (C0) of groups G1, G2 and G3 was similar (24.79±0.78ºC, 25.26±0.63ºC, 24.97±1.06ºC, respectively). The setting of the acrylic resin temporary crown resulted in a significant increase in the implant surface temperature of all groups. The mean thermal amplitude (ΔC) for groups G1, G2 and G3 were 6.79±1.02ºC, 6.61±0.94ºC, 6.65±1.26ºC, respectively. The mean time to maximum temperature (Tmax) for groups G1, G2 and G3 were 337.38±42.91 sec, 324.69±41.46 sec and 317.98±37.91 sec respectively (P>0.05). Direct application of auto-polymerizing resin to the titanium abutment of one-piece implants significantly increased the cervical implant surface temperature. Implant diameter did not influence the temperature changes.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Temperatura / Resinas Acrílicas / Implantes Dentários / Prótese Dentária Fixada por Implante / Coroas Idioma: En Revista: J Biol Regul Homeost Agents Assunto da revista: BIOLOGIA / BIOQUIMICA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Israel
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Temperatura / Resinas Acrílicas / Implantes Dentários / Prótese Dentária Fixada por Implante / Coroas Idioma: En Revista: J Biol Regul Homeost Agents Assunto da revista: BIOLOGIA / BIOQUIMICA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Israel