Your browser doesn't support javascript.
loading
Screening for glucose-6-phosphate dehydrogenase deficiency in neonates: a comparison between cord and peripheral blood samples.
AlSaif, Saif; Ponferrada, Ma Bella; AlKhairy, Khalid; AlTawil, Khalil; Sallam, Adel; Ahmed, Ibrahim; Khawaji, Mohammed; AlHathlol, Khalid; Baylon, Beverly; AlSuhaibani, Ahmed; AlBalwi, Mohammed.
Afiliação
  • AlSaif S; Division of Neonatology, Department of Pediatrics, King Abdulaziz Medical City, Ministry of National Guard Health Affairs, P.O. Box 22490, Riyadh, 11426, Kingdom of Saudi Arabia.
  • Ponferrada MB; Division of Neonatology, Department of Pediatrics, King Abdulaziz Medical City, Ministry of National Guard Health Affairs, P.O. Box 22490, Riyadh, 11426, Kingdom of Saudi Arabia.
  • AlKhairy K; Department of Pathology and Laboratory Medicine, King Abdulaziz Medical City, Ministry of National Guard Health Affairs, P.O. Box 22490, Riyadh, 11426, Kingdom of Saudi Arabia.
  • AlTawil K; Division of Neonatology, Department of Pediatrics, Prince Mohammad bin Abdulaziz Hospital, Ministry of National Guard Health Affairs, P.O. Box 40740, Al Madinah, Al Medina, 41511, Kingdom of Saudi Arabia.
  • Sallam A; Division of Neonatology, Department of Pediatrics, King Abdulaziz Medical City, Ministry of National Guard Health Affairs, P.O. Box 9515, Jeddah, 21423, Kingdom of Saudi Arabia.
  • Ahmed I; Division of Neonatology, Department of Pediatrics, King Abdulaziz Medical City, Ministry of National Guard Health Affairs, P.O. Box 22490, Riyadh, 11426, Kingdom of Saudi Arabia.
  • Khawaji M; Division of Neonatology, Department of Pediatrics, King Abdulaziz Medical City, Ministry of National Guard Health Affairs, P.O. Box 22490, Riyadh, 11426, Kingdom of Saudi Arabia.
  • AlHathlol K; Division of Neonatology, Department of Pediatrics, King Abdulaziz Medical City, Ministry of National Guard Health Affairs, P.O. Box 22490, Riyadh, 11426, Kingdom of Saudi Arabia.
  • Baylon B; Division of Neonatology, Department of Pediatrics, King Abdulaziz Medical City, Ministry of National Guard Health Affairs, P.O. Box 22490, Riyadh, 11426, Kingdom of Saudi Arabia.
  • AlSuhaibani A; Department of Pathology and Laboratory Medicine, King Abdulaziz Medical City, Ministry of National Guard Health Affairs, P.O. Box 22490, Riyadh, 11426, Kingdom of Saudi Arabia.
  • AlBalwi M; College of Medicine, King Saud bin Abdulaziz University for Health Sciences, P.O. Box 3660, Riyadh, 11481, Kingdom of Saudi Arabia.
BMC Pediatr ; 17(1): 159, 2017 Jul 11.
Article em En | MEDLINE | ID: mdl-28693459
ABSTRACT

BACKGROUND:

The use of cord blood in the neonatal screening for glucose-6-phosphate dehydrogenase (G6PD) deficiency is being done with increasing frequency but has yet to be adequately evaluated against the use of peripheral blood sample which is usually employed for confirmation. We sought to determine the incidence and gender distribution of G6PD deficiency, and compare the results of cord against peripheral blood in identifying G6PD DEFICIENCY neonates using quantitative enzyme activity assay.

METHODS:

We carried out a retrospective and cross-sectional study employing review of primary hospital data of neonates born in a tertiary care center from January to December 2008.

RESULTS:

Among the 8139 neonates with cord blood G6PD assays, an overall incidence of 2% for G6PD deficiency was computed. 79% of these were males and 21% were females with significantly more deficient males (p < .001). Gender-specific incidence was 3.06% for males and 0.85% for females. A subgroup analysis comparing cord and peripheral blood samples (n = 1253) showed a significantly higher mean G6PD value for peripheral than cord blood (15.12 ± 4.52 U/g and 14.52 ± 4.43 U/g, respectively, p = 0.0008). However, the proportion of G6PD deficient neonates did not significantly differ in the two groups (p = 0.79). Sensitivity of cord blood in screening for G6PD deficiency, using peripheral G6PD assay as a gold standard was 98.6% with a NPV of 99.5%.

CONCLUSION:

There was no difference between cord and peripheral blood samples in discriminating between G6PD deficient and non-deficient neonates. A significantly higher mean peripheral G6PD assay reinforces the use of cord blood for neonatal screening since it has substantially low false negative results.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Triagem Neonatal / Sangue Fetal / Glucosefosfato Desidrogenase / Deficiência de Glucosefosfato Desidrogenase Tipo de estudo: Diagnostic_studies / Incidence_studies / Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies / Screening_studies Limite: Female / Humans / Male / Newborn País/Região como assunto: Asia Idioma: En Revista: BMC Pediatr Assunto da revista: PEDIATRIA Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Triagem Neonatal / Sangue Fetal / Glucosefosfato Desidrogenase / Deficiência de Glucosefosfato Desidrogenase Tipo de estudo: Diagnostic_studies / Incidence_studies / Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies / Screening_studies Limite: Female / Humans / Male / Newborn País/Região como assunto: Asia Idioma: En Revista: BMC Pediatr Assunto da revista: PEDIATRIA Ano de publicação: 2017 Tipo de documento: Article