Your browser doesn't support javascript.
loading
Accurate charge densities from powder X-ray diffraction - a new version of the Aarhus vacuum imaging-plate diffractometer.
Tolborg, Kasper; Jørgensen, Mads R V; Christensen, Sebastian; Kasai, Hidetaka; Becker, Jacob; Walter, Peter; Dippel, Ann Christin; Als-Nielsen, Jens; Iversen, Bo B.
Afiliação
  • Tolborg K; Center for Materials Crystallography, Department of Chemistry and iNANO, Aarhus University, Langelandsgade 140, DK-8000 Aarhus C, Denmark.
  • Jørgensen MRV; Center for Materials Crystallography, Department of Chemistry and iNANO, Aarhus University, Langelandsgade 140, DK-8000 Aarhus C, Denmark.
  • Christensen S; Center for Materials Crystallography, Department of Chemistry and iNANO, Aarhus University, Langelandsgade 140, DK-8000 Aarhus C, Denmark.
  • Kasai H; Center for Materials Crystallography, Department of Chemistry and iNANO, Aarhus University, Langelandsgade 140, DK-8000 Aarhus C, Denmark.
  • Becker J; Center for Materials Crystallography, Department of Chemistry and iNANO, Aarhus University, Langelandsgade 140, DK-8000 Aarhus C, Denmark.
  • Walter P; PETRA III, Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, D-22607 Hamburg, Germany.
  • Dippel AC; PETRA III, Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, D-22607 Hamburg, Germany.
  • Als-Nielsen J; Niels Bohr Institute, University of Copenhagen, Universitetsparken 5, DK-2100 Copenhagen, Denmark.
  • Iversen BB; Center for Materials Crystallography, Department of Chemistry and iNANO, Aarhus University, Langelandsgade 140, DK-8000 Aarhus C, Denmark.
Acta Crystallogr B Struct Sci Cryst Eng Mater ; 73(Pt 4): 521-530, 2017 Aug 01.
Article em En | MEDLINE | ID: mdl-28762964
In recent years powder X-ray diffraction has proven to be a valuable alternative to single-crystal X-ray diffraction for determining electron-density distributions in high-symmetry inorganic materials, including subtle deformation in the core electron density. This was made possible by performing diffraction measurements in vacuum using high-energy X-rays at a synchrotron-radiation facility. Here we present a new version of our custom-built in-vacuum powder diffractometer with the sample-to-detector distance increased by a factor of four. In practice this is found to give a reduction in instrumental peak broadening by approximately a factor of three and a large improvement in signal-to-background ratio compared to the previous instrument. Structure factors of silicon at room temperature are extracted using a combined multipole-Rietveld procedure and compared with ab initio calculations and the results from the previous diffractometer. Despite some remaining issues regarding peak asymmetry, the new diffractometer yields structure factors of comparable accuracy to the previous diffractometer at low angles and improved accuracy at high angles. The high quality of the structure factors is further assessed by modelling of core electron deformation with results in good agreement with previous investigations.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Revista: Acta Crystallogr B Struct Sci Cryst Eng Mater Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Dinamarca País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Revista: Acta Crystallogr B Struct Sci Cryst Eng Mater Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Dinamarca País de publicação: Reino Unido