Your browser doesn't support javascript.
loading
Reduction of intradiscal pressure by the use of polycarbonate-urethane rods as compared to titanium rods in posterior thoracolumbar spinal fixation.
Jacobs, Eva; Roth, Alex K; Arts, Jacobus J; van Rhijn, Lodewijk W; Willems, Paul C.
Afiliação
  • Jacobs E; Department of Orthopaedic Surgery, CAPHRI Care and Public Health Research Institute, Maastricht University Medical Centre, P. Debyelaan 25, 6229 HX, Maastricht, The Netherlands. e.jacobs@maastrichtuniversity.nl.
  • Roth AK; Department of Orthopaedic Surgery, CAPHRI Care and Public Health Research Institute, Maastricht University Medical Centre, P. Debyelaan 25, 6229 HX, Maastricht, The Netherlands.
  • Arts JJ; Department of Orthopaedic Surgery, CAPHRI Care and Public Health Research Institute, Maastricht University Medical Centre, P. Debyelaan 25, 6229 HX, Maastricht, The Netherlands.
  • van Rhijn LW; Department of Orthopaedic Surgery, CAPHRI Care and Public Health Research Institute, Maastricht University Medical Centre, P. Debyelaan 25, 6229 HX, Maastricht, The Netherlands.
  • Willems PC; Department of Orthopaedic Surgery, CAPHRI Care and Public Health Research Institute, Maastricht University Medical Centre, P. Debyelaan 25, 6229 HX, Maastricht, The Netherlands.
J Mater Sci Mater Med ; 28(10): 148, 2017 Aug 21.
Article em En | MEDLINE | ID: mdl-28828753
ABSTRACT
Loss of sagittal alignment and balance in adult spinal deformity can cause severe pain, disability and progressive neurological deficit. When conservative treatment has failed, spinal fusion using rigid instrumentation is currently the salvage treatment to stop further curve progression. However, fusion surgery is associated with high revision rates due to instrumentation failure and proximal junctional failure, especially if patients also suffer from osteoporosis. To address these drawbacks, a less rigid rod construct is proposed, which is hypothesized to provide a more gradual transition of force and load distribution over spinal segments in comparison to stiff titanium rods. In this study, the effect of variation in rod stiffness on the intradiscal pressure (IDP) of fixed spinal segments during flexion-compression loading was assessed. An ex vivo multisegment (porcine) flexion-compression spine test comparing rigid titanium rods with more flexible polycarbonate-urethane (PCU) rods was used. An increase in peak IDP was found for both the titanium and PCU instrumentation groups as compared to the uninstrumented controls. The peak IDP for the spines instrumented with the PCU rods was significantly lower in comparison to the titanium instrumentation group. These results demonstrated the differences in mechanical load transfer characteristics between PCU and titanium rod constructs when subjected to flexion-compression loading. The concept of stabilization with a less rigid rod may be an alternative to fusion with rigid instrumentation, with the aim of decreasing mechanical stress on the instrumented segments and the possible benefit of a decrease in the incidence of screw pullout.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cimento de Policarboxilato / Titânio / Uretana / Fixadores Internos / Vértebras Lombares Limite: Animals Idioma: En Revista: J Mater Sci Mater Med Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cimento de Policarboxilato / Titânio / Uretana / Fixadores Internos / Vértebras Lombares Limite: Animals Idioma: En Revista: J Mater Sci Mater Med Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Holanda