Your browser doesn't support javascript.
loading
Reproducibility (Reliability and Agreement) of Post-exercise Hypotension.
Fecchio, Rafael Yokoyama; Chehuen, Marcel; Brito, Leandro Campos; Peçanha, Tiago; Queiroz, Andréia Cristiane Carrenho; de Moraes Forjaz, Claudia Lucia.
Afiliação
  • Fecchio RY; Exercise Hemodynamic Laboratory, School of Physical Education and Sport, University of São Paulo, São Paulo,Brazil.
  • Chehuen M; Exercise Hemodynamic Laboratory, School of Physical Education and Sport, University of São Paulo, São Paulo,Brazil.
  • Brito LC; Exercise Hemodynamic Laboratory, School of Physical Education and Sport, University of São Paulo, São Paulo,Brazil.
  • Peçanha T; Exercise Hemodynamic Laboratory, School of Physical Education and Sport, University of São Paulo, São Paulo,Brazil.
  • Queiroz ACC; Department of Physical Education - Governador Valadares, Federal University of Juiz de Fora, Minas Gerais, Brazil.
  • de Moraes Forjaz CL; Exercise Hemodynamic Laboratory, School of Physical Education and Sport, University of São Paulo, São Paulo,Brazil.
Int J Sports Med ; 38(13): 1029-1034, 2017 Nov.
Article em En | MEDLINE | ID: mdl-28922683
This study determined the reproducibility of post-exercise hypotension (PEH) calculated by the following methods: PEH_I=post-exercise BP - pre-exercise BP; PEH_II=post-exercise BP - post-control BP; and PEH_III=[(post-exercise BP - pre-exercise BP)-(post-control BP - pre-control BP)]. Twenty-five participants underwent four sessions divided in two blocks (test and retest). Each block consisted of one exercise and one control session. BP pressure was measured before and after the interventions. The presence of systematic error (paired t-tests), reliability [intraclass coefficient correlation (ICC)], and agreement [typical error (TE) and minimal detectable difference (MDD)] were evaluated. PEHs calculated by the three methods were similar between test and retest. For systolic PEH, ICC was>0.74, TE ranged from 2.6 to 4.6 mmHg and MDD from 7.2 to 12.8 mmHg for the three methods. For diastolic PEH, ICC was<0.48, TE ranged from 3.5 to 5.6 mmHg and MDD from 9.8 to 15.4 mmHg for the three methods. Thus, systolic PEH calculated by the three methods has good/excellent reliability, while diastolic PEH has fair/poor reliability. Regarding agreement, TE and MDD varied among the methods, which implies that the specific parameters given for each method should be used to estimate sample sizes for studies and the minimal individual difference considered real when comparing PEHs.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Determinação da Pressão Arterial / Hipotensão Pós-Exercício Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Int J Sports Med Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Brasil País de publicação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Determinação da Pressão Arterial / Hipotensão Pós-Exercício Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Int J Sports Med Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Brasil País de publicação: Alemanha