Your browser doesn't support javascript.
loading
Reliability of Peak Exercise Stroke Volume Assessment by Impedance Cardiography in Patients with Residual Right Outflow Tract Lesions After Congenital Heart Disease Repair.
Legendre, Antoine; Bonnet, D; Bosquet, L.
Afiliação
  • Legendre A; Pediatric Cardiology, centre de référence des malformations cardiaques congénitales complexes-M3C, Necker Hospital for Sick Children, Assistance publique des Hôpitaux de Paris, Paris, France. antoine.legendre@aphp.fr.
  • Bonnet D; Pediatric Cardiology, centre de référence des malformations cardiaques congénitales complexes-M3C, Necker Hospital for Sick Children, Assistance publique des Hôpitaux de Paris, Paris, France.
  • Bosquet L; Université Paris Descartes, Sorbonne Paris Cité, Paris, France.
Pediatr Cardiol ; 39(1): 45-50, 2018 Jan.
Article em En | MEDLINE | ID: mdl-28948370
ABSTRACT
Global ventricular response to exercise may be useful in follow-up of patients with residual right outflow tract lesions after congenital heart disease repair. In this context, impedance cardiography is considered accurate for stroke volume (SV) measurement during exercise testing, however, to date, only partial assessment of its reliability has been reported. We retrospectively evaluated relative and absolute reliability of peak SV by impedance cardiography during exercise using intraclass correlation (ICC) and standard error of measurement (SEM) in this population. Peak SV was measured in 30 young patients (mean age 14.4 years ± 2.1) with right ventricular outflow tract reconstruction who underwent two cardiopulmonary exercise tests at a mean one-year interval. SV was measured using a signal morphology impedance cardiography analysis device (PhysioFlow®) and was indexed to body surface area. ICC of peak indexed SV measurement was 0.80 and SEM was 10.5%. High heterogeneity was seen when comparing patients according to peak indexed SV; in patients with peak SV < 50 ml/m2 (15 patients), ICC rose to 0.95 and SEM dropped to 2.7%, while in patients with a peak SV > 50 ml/m2 relative and absolute reliability decreased (ICC = 0.45, SEM = 12.2%). Peak exercise SV assessment by a PhysioFlow® device represents a highly reliable method in patients with residual right outflow tract lesions after congenital heart disease repair, especially in patients with peak SV < 50 ml/m2. In this latter group, a peak SV decrease > 7.3% (corresponding to the minimum "true" difference) should be considered a clinically-relevant decrease in global ventricular performance and taken into account when deciding whether to perform residual lesion removal.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Volume Sistólico / Obstrução do Fluxo Ventricular Externo / Cardiografia de Impedância / Cardiopatias Congênitas Tipo de estudo: Observational_studies Limite: Adolescent / Child / Female / Humans / Male Idioma: En Revista: Pediatr Cardiol Ano de publicação: 2018 Tipo de documento: Article País de afiliação: França

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Volume Sistólico / Obstrução do Fluxo Ventricular Externo / Cardiografia de Impedância / Cardiopatias Congênitas Tipo de estudo: Observational_studies Limite: Adolescent / Child / Female / Humans / Male Idioma: En Revista: Pediatr Cardiol Ano de publicação: 2018 Tipo de documento: Article País de afiliação: França