Ability of pulse wave transit time to detect changes in stroke volume and to estimate cardiac output compared to thermodilution technique in isoflurane-anaesthetised dogs.
Sano, H; Chambers, J P.
Afiliação
  • Sano H; Institute of Veterinary, Animal & Biomedical Sciences, College of Sciences, Massey University, Palmerston North, New Zealand. Electronic address: H.Sano@massey.ac.nz.
  • Chambers JP; Institute of Veterinary, Animal & Biomedical Sciences, College of Sciences, Massey University, Palmerston North, New Zealand.
Vet Anaesth Analg ; 44(5): 1057-1067, 2017 Sep.
Article em En | MEDLINE | ID: mdl-29029934
OBJECTIVE: To evaluate the ability of pulse wave transit time (PWTT) to detect changes in stroke volume (SV) and to estimate cardiac output (CO) compared with the thermodilution technique in isoflurane-anaesthetized dogs. STUDY DESIGN: Prospective, experimental study. ANIMALS: Eight adult laboratory dogs. METHODS: The dogs were anaesthetized with isoflurane and mechanically ventilated. Reference CO (TDCO) was measured via a pulmonary artery catheter using the thermodilution technique and reference SV (TDSV) was calculated. PWTT was calculated as the time from the electrocardiogram R-wave peak to the rise point of the pulse oximeter wave. Estimated CO (esCO) was derived from PWTT after calibration with arterial pulse pressure (both non-invasive and invasive methods) and TDCO. Haemodynamic changes were induced by administration of phenylephrine (vasoconstriction), high isoflurane (vasodilatation and negative inotropy) and dobutamine (vasodilatation and positive inotropy). Trending between percentage change in PWTT and TDSV was assessed using concordance analysis and receiver operator characteristic (ROC) curve. The agreement between esCO and TDCO was evaluated using the Bland-Altman method. RESULTS: The direction of percentage change between consecutive PWTT and the corresponding TDSV showed a concordance rate of 95%, with correlation coefficients of -0.86 (p<0.001). Area under the ROC curve for the change in PWTT to detect 15% change in TDSV was 0.91 (p<0.001). TDCO compared with esCO calibrated with invasive and non-invasive blood pressure showed a bias (precision of agreement) of 0.58 (1.54) and 0.57 (1.59) L minute-1 with a percentage error of ±61% and ±63%, respectively. CONCLUSIONS AND CLINICAL RELEVANCE: In isoflurane-anaesthetized dogs, PWTT showed a good trending ability to detect 15% changes in SV. This technique is easy to use, inexpensive, non-invasive and could become routine anaesthetic monitoring. However, the agreement between absolute esCO and TDCO was unacceptable.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Volume Sistólico / Termodiluição / Débito Cardíaco / Anestésicos Inalatórios / Análise de Onda de Pulso / Isoflurano / Anestesia por Inalação Tipo de estudo: Prognostic_studies Limite: Animals Idioma: En Revista: Vet Anaesth Analg Assunto da revista: ANESTESIOLOGIA / MEDICINA VETERINARIA Ano de publicação: 2017 Tipo de documento: Article País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Volume Sistólico / Termodiluição / Débito Cardíaco / Anestésicos Inalatórios / Análise de Onda de Pulso / Isoflurano / Anestesia por Inalação Tipo de estudo: Prognostic_studies Limite: Animals Idioma: En Revista: Vet Anaesth Analg Assunto da revista: ANESTESIOLOGIA / MEDICINA VETERINARIA Ano de publicação: 2017 Tipo de documento: Article País de publicação: Estados Unidos