Your browser doesn't support javascript.
loading
Determination of Monensin in Bovine Tissues: A Bridging Study Comparing the Bioautographic Method (FSIS CLG-MON) with a Liquid Chromatography-Tandem Mass Spectrometry Method (OMA 2011.24).
Mizinga, Kemmy M; Burnett, Thomas J; Brunelle, Sharon L; Wallace, Michael A; Coleman, Mark R.
Afiliação
  • Mizinga KM; Elanco Animal Health, 2500 Innovation Way, Greenfield, IN 46140.
  • Burnett TJ; Elanco Animal Health, 2500 Innovation Way, Greenfield, IN 46140.
  • Brunelle SL; Brunelle Biotech Consulting, 6620 NW Burgundy Dr., Corvallis, OR 97330.
  • Wallace MA; MPI Research, Inc., 3058 Research Dr., State College, PA 16801.
  • Coleman MR; Mark R. Coleman, PhD, Consulting, LLC, 126 Yorkshire Blvd. E, Indianapolis, IN 46229.
J AOAC Int ; 101(3): 891-896, 2018 May 01.
Article em En | MEDLINE | ID: mdl-29191256
ABSTRACT
The U.S. Department of Agriculture, Food Safety Inspection Service regulatory method for monensin, Chemistry Laboratory Guidebook CLG-MON, is a semiquantitative bioautographic method adopted in 1991. Official Method of AnalysisSM (OMA) 2011.24, a modern quantitative and confirmatory LC-tandem MS method, uses no chlorinated solvents and has several advantages, including ease of use, ready availability of reagents and materials, shorter run-time, and higher throughput than CLG-MON. Therefore, a bridging study was conducted to support the replacement of method CLG-MON with OMA 2011.24 for regulatory use. Using fortified bovine tissue samples, CLG-MON yielded accuracies of 80-120% in 44 of the 56 samples tested (one sample had no result, six samples had accuracies of >120%, and five samples had accuracies of 40-160%), but the semiquantitative nature of CLG-MON prevented assessment of precision, whereas OMA 2011.24 had accuracies of 88-110% and RSDr of 0.00-15.6%. Incurred residue results corroborated these results, demonstrating improved accuracy (83.3-114%) and good precision (RSDr of 2.6-20.5%) for OMA 2011.24 compared with CLG-MON (accuracy generally within 80-150%, with exceptions). Furthermore, χ2 analysis revealed no statistically significant difference between the two methods. Thus, the microbiological activity of monensin correlated with the determination of monensin A in bovine tissues, and OMA 2011.24 provided improved accuracy and precision over CLG-MON.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Monensin / Testes de Sensibilidade Microbiana / Contaminação de Alimentos / Cromatografia Líquida / Espectrometria de Massas em Tandem Limite: Animals Idioma: En Revista: J AOAC Int Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Monensin / Testes de Sensibilidade Microbiana / Contaminação de Alimentos / Cromatografia Líquida / Espectrometria de Massas em Tandem Limite: Animals Idioma: En Revista: J AOAC Int Ano de publicação: 2018 Tipo de documento: Article