Your browser doesn't support javascript.
loading
Development of HPLC with fluorescent detection using NBD-F for the quantification of colistin sulfate in rat plasma and its pharmacokinetic applications.
Ouchi, Sui; Matsumoto, Kazuaki; Okubo, Maki; Yokoyama, Yuta; Kizu, Junko.
Afiliação
  • Ouchi S; Division of Practical Pharmacy, Keio University Faculty of Pharmacy, Tokyo, Japan.
  • Matsumoto K; Division of Practical Pharmacy, Keio University Faculty of Pharmacy, Tokyo, Japan.
  • Okubo M; Division of Practical Pharmacy, Keio University Faculty of Pharmacy, Tokyo, Japan.
  • Yokoyama Y; Division of Practical Pharmacy, Keio University Faculty of Pharmacy, Tokyo, Japan.
  • Kizu J; Division of Practical Pharmacy, Keio University Faculty of Pharmacy, Tokyo, Japan.
Biomed Chromatogr ; 32(5): e4167, 2018 May.
Article em En | MEDLINE | ID: mdl-29235137
ABSTRACT
Colistin sulfate, composed of a mixture of colistin A sulfate (CLA) and colistin B sulfate (CLB), is available for treating life-threatening infections caused by multidrug-resistant Gram-negative bacteria. In this study, the CLA and CLB were quantified separately. Colistin sulfate was extracted from rat plasma with a solid-phase extraction C18 cartridge and reacted with 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F), and the fluorescent derivatives were subjected to reversed-phase high-performance liquid chromatography analysis and used to investigate the pharmacokinetics of CLA and CLB in rat plasma. The recovery rates of CLA and CLB were 41.2 ± 4.4 and 45.5 ± 3.1%, respectively. The recovery rate calculated from the total area of CLA and CLB was 43.9 ± 3.6%. When 2 mm NBD-F and 10 mm boric acid buffer (pH 9.5) were added to colistin sulfate, the highest recovery rate was obtained. The best heating time was 5 min at 60°C. The lower limits of quantification for CLA, CLB and the total area of CLA and CLB were 0.05, 0.05 and 0.1 µg/mL; the coefficients of variations were 13.5, 14.5 and 14.1%, respectively. This method was found to have acceptable linearity, precision and accuracy, and has been successfully applied to a pharmacokinetic study in rat plasma.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cromatografia Líquida de Alta Pressão / Colistina Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Revista: Biomed Chromatogr Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cromatografia Líquida de Alta Pressão / Colistina Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Revista: Biomed Chromatogr Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Japão