Quantified frequency-domain optical coherence tomography analysis for the thin-high signals on restenotic tissue after paclitaxel-coated balloon angioplasty.
Kawashima, Hideyuki; Suzuki, Nobuaki; Katayama, Taiga; Takahashi, Shinji; Okabe, Ryuta; Takamura, Shintaro; Watanabe, Yusuke; Kyono, Hiroyuki; Kozuma, Ken.
Afiliação
  • Kawashima H; Department of Medicine, Teikyo University School of Medicine, Tokyo, Japan.
  • Suzuki N; Department of Medicine, Teikyo University School of Medicine, Tokyo, Japan. nsuzu@bronze.ocn.ne.jp.
  • Katayama T; Fourth Department of Internal Medicine, Teikyo University School of Medicine, 5-1-1 Futako, Takatsu-ku, Kawasaki, Japan. nsuzu@bronze.ocn.ne.jp.
  • Takahashi S; Department of Medicine, Teikyo University School of Medicine, Tokyo, Japan.
  • Okabe R; Department of Medicine, Teikyo University School of Medicine, Tokyo, Japan.
  • Takamura S; Department of Medicine, Teikyo University School of Medicine, Tokyo, Japan.
  • Watanabe Y; Department of Medicine, Teikyo University School of Medicine, Tokyo, Japan.
  • Kyono H; Department of Medicine, Teikyo University School of Medicine, Tokyo, Japan.
  • Kozuma K; Department of Medicine, Teikyo University School of Medicine, Tokyo, Japan.
Heart Vessels ; 33(6): 583-589, 2018 Jun.
Article em En | MEDLINE | ID: mdl-29249006
ABSTRACT
Thin-high signals (THS), detectable by optical coherence tomography (OCT), represent the paclitaxel coverage of in-stent restenotic tissue. This study was conducted to assess the relationship between THS and angiographic outcomes by means of quantified post-procedural frequency-domain OCT (FD-OCT) analysis. From January 2014 to July 2016, 41 patients underwent FD-OCT-guided percutaneous coronary intervention using paclitaxel-coated balloon (PCB) to prevent in-stent restenosis. Of these, we retrospectively enrolled 32 patients (38 lesions) who underwent a 6- to 9-month follow-up angiogram. THS were assessed quantitatively, as THS length and lumen perimeter length were measured using semi-automated software; %THS was calculated by the following formula; total THS area/lumen perimeter area × 100. THS were detected in all 38 lesions that had undergone PCB angioplasty. THS and %THS were significantly higher in lesions without binary restenosis (3.34 ± 2.11 vs. 11.48 ± 8.53 mm2, p = 0.001 and 1.49 ± 0.73 vs. 4.42 ± 2.71%, p = 0.001, respectively). Values for THS, which indicates the paclitaxel coverage on restenotic tissue, are associated with reducing restenosis after PCB for in-stent restenosis.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Angioplastia Coronária com Balão / Paclitaxel / Reestenose Coronária / Tomografia de Coerência Óptica / Stents Farmacológicos Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male Idioma: En Revista: Heart Vessels Assunto da revista: CARDIOLOGIA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Angioplastia Coronária com Balão / Paclitaxel / Reestenose Coronária / Tomografia de Coerência Óptica / Stents Farmacológicos Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male Idioma: En Revista: Heart Vessels Assunto da revista: CARDIOLOGIA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Japão