Your browser doesn't support javascript.
loading
Cilostazol-Loaded Poly(ε-Caprolactone) Electrospun Drug Delivery System for Cardiovascular Applications.
Rychter, Marek; Baranowska-Korczyc, Anna; Milanowski, Bartlomiej; Jarek, Marcin; Maciejewska, Barbara M; Coy, Emerson L; Lulek, Janina.
Afiliação
  • Rychter M; Department of Pharmaceutical Technology, Faculty of Pharmacy, Poznan University of Medical Sciences, Grunwaldzka 6, 60-780, Poznan, Poland. mrychter@ump.edu.pl.
  • Baranowska-Korczyc A; NanoBioMedical Center, Adam Mickiewicz University Poznan, Umultowska 85, 61-614, Poznan, Poland. mrychter@ump.edu.pl.
  • Milanowski B; NanoBioMedical Center, Adam Mickiewicz University Poznan, Umultowska 85, 61-614, Poznan, Poland.
  • Jarek M; Department of Pharmaceutical Technology, Faculty of Pharmacy, Poznan University of Medical Sciences, Grunwaldzka 6, 60-780, Poznan, Poland.
  • Maciejewska BM; NanoBioMedical Center, Adam Mickiewicz University Poznan, Umultowska 85, 61-614, Poznan, Poland.
  • Coy EL; NanoBioMedical Center, Adam Mickiewicz University Poznan, Umultowska 85, 61-614, Poznan, Poland.
  • Lulek J; Department of Macromolecular Physics, Faculty of Physics, Adam Mickiewicz University, Umultowska 85, 61-614, Poznan, Poland.
Pharm Res ; 35(2): 32, 2018 Jan 16.
Article em En | MEDLINE | ID: mdl-29368067
PURPOSE: The study discusses the value of electrospun cilostazol-loaded (CIL) polymer structures for potential vascular implant applications. METHODS: Biodegradable polycaprolactone (PCL) fibers were produced by electrospinning on a rotating drum collector. Three different concentrations of CIL: 6.25%, 12.50% and 18.75% based on the amount of polymer, were incorporated into the fibers. The fibers were characterized by their size, shape and orientation. Materials characterization was carried out by Fourier Transformed Infrared spectroscopy (FTIR), Raman spectroscopy, differential scanning calorimetry (DSC) and X-ray diffraction (XRD). In vitro drug release study was conducted using flow-through cell apparatus (USP 4). RESULTS: Three-dimensional structures characterized by fibers diameter ranging from 0.81 to 2.48 µm were in the range required for cardiovascular application. DSC and XRD confirmed the presence of CIL in the electrospun fibers. FTIR and Raman spectra confirmed CIL polymorphic form. Elastic modulus values for PCL and the CIL-loaded PCL fibers were in the range from 0.6 to 1.1 GPa. The in vitro release studies were conducted and revealed drug dissolution in combination with diffusion and polymer relaxation as mechanisms for CIL release from the polymer matrix. CONCLUSIONS: The release profile of CIL and nanomechanical properties of all formulations of PCL fibers demonstrate that the cilostazol loaded PCL fibers are an efficient delivery system for vascular implant application.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Trombose / Prótese Vascular / Inibidores da Agregação Plaquetária / Sistemas de Liberação de Medicamentos / Cilostazol Tipo de estudo: Etiology_studies Limite: Humans Idioma: En Revista: Pharm Res Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Polônia País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Trombose / Prótese Vascular / Inibidores da Agregação Plaquetária / Sistemas de Liberação de Medicamentos / Cilostazol Tipo de estudo: Etiology_studies Limite: Humans Idioma: En Revista: Pharm Res Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Polônia País de publicação: Estados Unidos