Your browser doesn't support javascript.
loading
IL8 and IL16 levels indicate serum and plasma quality.
Kofanova, Olga; Henry, Estelle; Aguilar Quesada, Rocio; Bulla, Alexandre; Navarro Linares, Hector; Lescuyer, Pierre; Shea, Kathi; Stone, Mars; Tybring, Gunnel; Bellora, Camille; Betsou, Fay.
Afiliação
  • Kofanova O; Integrated Biobank of Luxembourg, Strassen, Luxembourg.
  • Henry E; Integrated Biobank of Luxembourg, Strassen, Luxembourg.
  • Aguilar Quesada R; Biobanco del Sistema Sanitario Público de Andalucía (BSSPA), Granada, Spain.
  • Bulla A; Sérothèque Centrale, Département de Médecine Génétique et de Laboratoire, Hôpitaux Universitaires de Genève, Genève, Switzerland.
  • Navarro Linares H; Biobanco del Sistema Sanitario Público de Andalucía (BSSPA), Granada, Spain.
  • Lescuyer P; Sérothèque Centrale, Département de Médecine Génétique et de Laboratoire, Hôpitaux Universitaires de Genève, Genève, Switzerland.
  • Shea K; Precision for Medicine, Frederick, MD, USA.
  • Stone M; Blood Systems Research Institute, San Francisco, CA, USA.
  • Tybring G; Karolinska Instituten Biobank, Stockholm, Sweden.
  • Bellora C; Integrated Biobank of Luxembourg, Strassen, Luxembourg.
  • Betsou F; Integrated Biobank of Luxembourg, Strassen, Luxembourg.
Clin Chem Lab Med ; 56(7): 1054-1062, 2018 06 27.
Article em En | MEDLINE | ID: mdl-29425105
ABSTRACT

BACKGROUND:

Longer pre-centrifugation times alter the quality of serum and plasma samples. Markers for such delays in sample processing and hence for the sample quality, have been identified.

METHODS:

Twenty cytokines in serum, EDTA plasma and citrate plasma samples were screened for changes in concentration induced by extended blood pre-centrifugation delays at room temperature. The two cytokines that showed the largest changes were further validated for their "diagnostic performance" in identifying serum or plasma samples with extended pre-centrifugation times.

RESULTS:

In this study, using R&D Systems ELISA kits, EDTA plasma samples and serum samples with a pre-centrifugation delay longer than 24 h had an IL16 concentration higher than 313 pg/mL, and an IL8 concentration higher than 125 pg/mL, respectively. EDTA plasma samples with a pre-centrifugation delay longer than 48 h had an IL16 concentration higher than 897 pg/mL, citrate plasma samples had an IL8 concentration higher than 21.5 pg/mL and serum samples had an IL8 concentration higher than 528 pg/mL.

CONCLUSIONS:

These robust and accurate tools, based on simple and commercially available ELISA assays can greatly facilitate qualification of serum and plasma legacy collections with undocumented pre-analytics.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Interleucina-8 / Interleucina-16 Tipo de estudo: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Clin Chem Lab Med Assunto da revista: QUIMICA CLINICA / TECNICAS E PROCEDIMENTOS DE LABORATORIO Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Luxemburgo

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Interleucina-8 / Interleucina-16 Tipo de estudo: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Clin Chem Lab Med Assunto da revista: QUIMICA CLINICA / TECNICAS E PROCEDIMENTOS DE LABORATORIO Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Luxemburgo