Accurate Pan-Cancer Molecular Diagnosis of Microsatellite Instability by Single-Molecule Molecular Inversion Probe Capture and High-Throughput Sequencing.
Waalkes, Adam; Smith, Nahum; Penewit, Kelsi; Hempelmann, Jennifer; Konnick, Eric Q; Hause, Ronald J; Pritchard, Colin C; Salipante, Stephen J.
Afiliação
  • Waalkes A; Department of Laboratory Medicine, University of Washington, Seattle, WA.
  • Smith N; Department of Laboratory Medicine, University of Washington, Seattle, WA.
  • Penewit K; Department of Laboratory Medicine, University of Washington, Seattle, WA.
  • Hempelmann J; Department of Laboratory Medicine, University of Washington, Seattle, WA.
  • Konnick EQ; Department of Laboratory Medicine, University of Washington, Seattle, WA.
  • Hause RJ; Department of Genome Sciences, University of Washington, Seattle, WA.
  • Pritchard CC; Department of Laboratory Medicine, University of Washington, Seattle, WA.
  • Salipante SJ; Department of Laboratory Medicine, University of Washington, Seattle, WA; stevesal@uw.edu.
Clin Chem ; 64(6): 950-958, 2018 06.
Article em En | MEDLINE | ID: mdl-29632127
ABSTRACT

BACKGROUND:

Microsatellite instability (MSI) is an emerging actionable phenotype in oncology that informs tumor response to immune checkpoint pathway immunotherapy. However, there remains a need for MSI diagnostics that are low cost, highly accurate, and generalizable across cancer types. We developed a method for targeted high-throughput sequencing of numerous microsatellite loci with pan-cancer informativity for MSI using single-molecule molecular inversion probes (smMIPs).

METHODS:

We designed a smMIP panel targeting 111 loci highly informative for MSI across cancers. We developed an analytical framework taking advantage of smMIP-mediated error correction to specifically and sensitively detect instability events without the need for typing matched normal material.

RESULTS:

Using synthetic DNA mixtures, smMIPs were sensitive to at least 1% MSI-positive cells and were highly consistent across replicates. The fraction of identified unstable microsatellites discriminated tumors exhibiting MSI from those lacking MSI with high accuracy across colorectal (100% diagnostic sensitivity and specificity), prostate (100% diagnostic sensitivity and specificity), and endometrial cancers (95.8% diagnostic sensitivity and 100% specificity). MSI-PCR, the current standard-of-care molecular diagnostic for MSI, proved equally robust for colorectal tumors but evidenced multiple false-negative results in prostate (81.8% diagnostic sensitivity and 100% specificity) and endometrial (75.0% diagnostic sensitivity and 100% specificity) tumors.

CONCLUSIONS:

smMIP capture provides an accurate, diagnostically sensitive, and economical means to diagnose MSI across cancer types without reliance on patient-matched normal material. The assay is readily scalable to large numbers of clinical samples, enables automated and quantitative analysis of microsatellite instability, and is readily standardized across clinical laboratories.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Instabilidade de Microssatélites / Sequenciamento de Nucleotídeos em Larga Escala / Neoplasias Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Clin Chem Assunto da revista: QUIMICA CLINICA Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Instabilidade de Microssatélites / Sequenciamento de Nucleotídeos em Larga Escala / Neoplasias Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Clin Chem Assunto da revista: QUIMICA CLINICA Ano de publicação: 2018 Tipo de documento: Article