Your browser doesn't support javascript.
loading
Diagnostic Performance of Shear Wave Elastography in Patients With Autoimmune Liver Disease.
Li, Changtian; Dhyani, Manish; Bhan, Atul K; Grajo, Joseph R; Pratt, Daniel S; Gee, Michael S; Samir, Anthony E.
Afiliação
  • Li C; Department of Ultrasound, The Southern Building, Chinese People's Liberation Army General Hospital, Beijing, China.
  • Dhyani M; Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA.
  • Bhan AK; Department of Pathology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA.
  • Grajo JR; Department of Radiology, Division of Abdominal Imaging, University of Florida College of Medicine, Gainesville, Florida, USA.
  • Pratt DS; Autoimmune and Cholestatic Liver Center, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA.
  • Gee MS; Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA.
  • Samir AE; Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA.
J Ultrasound Med ; 38(1): 103-111, 2019 Jan.
Article em En | MEDLINE | ID: mdl-29761535
OBJECTIVES: To assess performance of shear wave elastography for evaluation of fibrosis and the histologic stage in patients with autoimmune liver disease (ALD) and to validate previously established advanced fibrosis cutoff values in this cohort. METHODS: Shear wave elastography was performed on patients with ALD with an Aixplorer ultrasound system (SuperSonic Imagine, Aix-en-Provence, France) using an SC6-1 transducer. The median estimated tissue Young modulus was calculated from sets of 8 to 10 elastograms. A blinded, subspecialty-trained pathologist reviewed biopsy specimens. The METAVIR classification was used to stage liver fibrosis and necroinflammation. Steatosis was graded from 0 to 4+. The Kendall τ-b correlation test was performed to identify the correlation between the estimated tissue Young modulus and fibrosis, steatosis, and the necroinflammatory score. The Spearman correlation test was performed to identify the correlation between the estimated tissue Young modulus and clinical data. The diagnostic performance of shear wave elastography for differentiating METAVIR stage F2 or higher from F0 and F1 fibrosis was evaluated by a receiver operating characteristic (ROC) curve analysis. RESULTS: Fifty-one patients with ALD were analyzed. The estimated tissue Young modulus was positively correlated with the fibrosis stage and necroinflammation score (r = 0.386; P < .001; r = 0.338; P = .002, respectively) but not steatosis (r = -0.091; P = .527). Serum aspartate aminotransferase, alanine aminotransferase, and total bilirubin values were positively correlated with the estimated tissue Young modulus (r = 0.501; P < .001; r = 0.44; P = .001; r = 0.291; P = .038). The serum albumin value was negatively correlated (r = -0.309; P = .033). The area under the ROC curve was 0.781 (95% confidence interval, 0.641-0.921) for distinguishing F2 or greater fibrosis from F0 and F1 fibrosis. Based on the ROC curve, an optimal cutoff value of 9.15 kPa was identified (sensitivity, 83.3%; specificity, 72.7%). CONCLUSIONS: Shear wave elastography is a novel noninvasive adjunct to liver biopsy in evaluation and staging of patients with ALD, showing the potential for serial evaluations of disease progression and treatment responses.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doenças Autoimunes / Técnicas de Imagem por Elasticidade / Hepatopatias Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Female / Humans / Male / Middle aged Idioma: En Revista: J Ultrasound Med Ano de publicação: 2019 Tipo de documento: Article País de afiliação: China País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doenças Autoimunes / Técnicas de Imagem por Elasticidade / Hepatopatias Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Female / Humans / Male / Middle aged Idioma: En Revista: J Ultrasound Med Ano de publicação: 2019 Tipo de documento: Article País de afiliação: China País de publicação: Reino Unido