Your browser doesn't support javascript.
loading
The relationship between inertial measurement unit-derived 'force signatures' and ground reaction forces during cricket pace bowling.
Callaghan, Samuel J; Lockie, Robert G; Andrews, Warren A; Chipchase, Robert F; Nimphius, Sophia.
Afiliação
  • Callaghan SJ; School of Life Sciences, Pharmacy and Chemistry, Kingston University, London, UK.
  • Lockie RG; Centre for Sports and Exercise Science Research, School of Medical and Health Sciences, Edith Cowan University, Joondalup, Australia.
  • Andrews WA; High Performance Department, Western Australian Cricket Association, Perth, Australia.
  • Chipchase RF; Department of Kinesiology, California State University, Fullerton, CA, USA.
  • Nimphius S; High Performance Department, Western Australian Cricket Association, Perth, Australia.
Sports Biomech ; 19(3): 307-321, 2020 Jun.
Article em En | MEDLINE | ID: mdl-29767577
This study assessed the reliability and validity of segment measured accelerations in comparison to front foot contact (FFC) ground reaction force (GRF) during the delivery stride for cricket pace bowlers. Eleven recreational bowlers completed a 30-delivery bowling spell. Trunk- and tibia-mounted inertial measurement units (IMUs) were used to measure accelerations, converted to force, for comparisons to force plate GRF discrete measures. These measures included peak force, impulse and the continuous force-time curve in the vertical and braking (horizontal) planes. Reliability and validity was determined by intra-class correlation coefficients (ICC), coefficient of variation (CV), Bland-Altman plots, paired sample t-tests, Pearson's correlation and one-dimensional (1D) statistical parametrical mapping (SPM). All ICC (0.90-0.98) and CV (4.23-7.41%) were acceptable, except for tibia-mounted IMU braking peak force (CV = 12.44%) and impulse (CV = 18.17%) and trunk vertical impulse (CV = 17.93%). Bland-Altman plots revealed wide limits of agreement between discrete IMU force signatures and force plate GRF. The 1D SPM outlined numerous significant (p < 0.01) differences between trunk- and tibia-located IMU-derived measures and force plate GRF traces in vertical and braking (horizontal) planes. The trunk- and tibia-mounted IMUs appeared to not represent the GRF experienced during pace bowling FFC when compared to a gold-standard force plate.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Acelerometria / Críquete Tipo de estudo: Observational_studies / Prevalence_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: Sports Biomech Assunto da revista: MEDICINA ESPORTIVA Ano de publicação: 2020 Tipo de documento: Article País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Acelerometria / Críquete Tipo de estudo: Observational_studies / Prevalence_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: Sports Biomech Assunto da revista: MEDICINA ESPORTIVA Ano de publicação: 2020 Tipo de documento: Article País de publicação: Reino Unido