Your browser doesn't support javascript.
loading
A label-free electrochemiluminescent immunosensor for glutamate decarboxylase antibody detection on AuNPs supporting interface.
Ma, Xuexue; Fang, Chen; Yan, Jilin; Zhao, Qun; Tu, Yifeng.
Afiliação
  • Ma X; Institute of Analytical Chemistry, Dushu Lake Campus, Soochow University, Industrial Park, Suzhou 215123, PR China.
  • Fang C; Institute of Analytical Chemistry, Dushu Lake Campus, Soochow University, Industrial Park, Suzhou 215123, PR China; Second Affiliated Hospital, Soochow University, Suzhou 215004, PR China.
  • Yan J; Institute of Analytical Chemistry, Dushu Lake Campus, Soochow University, Industrial Park, Suzhou 215123, PR China.
  • Zhao Q; Institute of Analytical Chemistry, Dushu Lake Campus, Soochow University, Industrial Park, Suzhou 215123, PR China; College of Chemistry and Chemical Engineering, Nantong University, Nantong 226019, PR China. Electronic address: 25315885@qq.com.
  • Tu Y; Institute of Analytical Chemistry, Dushu Lake Campus, Soochow University, Industrial Park, Suzhou 215123, PR China. Electronic address: tuyf@suda.edu.cn.
Talanta ; 186: 206-214, 2018 Aug 15.
Article em En | MEDLINE | ID: mdl-29784351
ABSTRACT
In this paper, we will describe a novel lable-free electrochemiluminescent (ECL) immunosensor for the detection of glutamate decarboxylase antibody (GADA) in which Au nanoparticles (AuNPs) had pre-functionalized the indium tin oxide (ITO) glass to support the sensing interface. The preparation of the basal electrode only need a simple two-step drop coating, a thin polymer of hydrolyzed 3-aminopropyl trimethoxysilane, and the AuNPs gel on the ITO substrate. The AuNPs not only enhanced the ECL signal of luminol, but also acted to immobilize the glutamate decarboxylase (GAD) to build the sensing host. This immunosensor exhibits excellent specificity, reproducibility and stability. On resultant sensor, after the direct immunoreaction, the decreased ECL intensity has a good linear regression toward the logarithm of GADA concentration in the range of 0.30 ng mL-1 to 50 ng mL-1 with a detection limit of 0.10 ng mL-1. The proposed senor has prospective capability for the clinical detection of GADA in human serums, which had important value for diagnosis and precaution of type-1 diabetes or latent autoimmune diabetes in adult (LADA).
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imunoensaio / Técnicas Biossensoriais / Técnicas Eletroquímicas / Glutamato Descarboxilase / Medições Luminescentes / Anticorpos Tipo de estudo: Diagnostic_studies Limite: Adult / Humans Idioma: En Revista: Talanta Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imunoensaio / Técnicas Biossensoriais / Técnicas Eletroquímicas / Glutamato Descarboxilase / Medições Luminescentes / Anticorpos Tipo de estudo: Diagnostic_studies Limite: Adult / Humans Idioma: En Revista: Talanta Ano de publicação: 2018 Tipo de documento: Article