Your browser doesn't support javascript.
loading
Novel Stereoscopic Optical System for Objectively Measuring Above-Surface Scar Volume-First-Time Quantification of Responses to Various Treatment Modalities.
Salameh, Fares; Koren, Amir; Sprecher, Eli; Artzi, Ofir.
Afiliação
  • Salameh F; Department of Dermatology, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel.
  • Koren A; Department of Dermatology, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel.
  • Sprecher E; Department of Dermatology, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel.
  • Artzi O; Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.
Dermatol Surg ; 44(6): 848-854, 2018 Jun.
Article em En | MEDLINE | ID: mdl-29799828
BACKGROUND: Current approaches use subjective semiquantitative or cumbersome objective methodologies to assess physical characteristics of hypertrophic and keloid scars. OBJECTIVE: This pilot study aimed to evaluate the accuracy and feasibility of a new stereoscopic optical and high-resolution 3-dimensional imaging system, for objectively measuring changes in above-surface scar volume after various interventions. METHODS: Feasibility and accuracy were assessed by monitoring the above-surface scar volume of 5 scars in 2 patients for 5 successive months. Above-surface scar volume and Vancouver Scar Scale scores and the investigator and patient volume improvement assessment scores were assessed before and 12 weeks after last intervention. RESULTS: Scar volume measured by the imaging system correlated significantly with the gold standard (actual weight). The greatest volume reduction followed a combination of cryotherapy and intralesional triamcinolone acetonide and 5-fluorouracil injections in Patient 1 and a combination of pulse dye laser and intralesional triamcinolone acetonide injections in Patient 2. CONCLUSION: The new stereoscopic optical system is a valid, accurate, and practical objective method for assessing scar volume and for monitoring treatment response. It is more sensitive and accurate than semiquantitative objective scales. Further studies with a higher number of patients and scars are required to increase the measurement validity of the system.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cicatriz Hipertrófica / Imageamento Tridimensional / Dispositivos Ópticos / Queloide Limite: Adult / Female / Humans Idioma: En Revista: Dermatol Surg Assunto da revista: DERMATOLOGIA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Israel País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cicatriz Hipertrófica / Imageamento Tridimensional / Dispositivos Ópticos / Queloide Limite: Adult / Female / Humans Idioma: En Revista: Dermatol Surg Assunto da revista: DERMATOLOGIA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Israel País de publicação: Estados Unidos