Your browser doesn't support javascript.
loading
Optimization of ozonation and peroxone process for simultaneous control of micropollutants and bromate in wastewater.
Phattarapattamawong, Songkeart; Kaiser, Andreas Marius; Saracevic, Ernis; Schaar, Heidemarie Paula; Krampe, Jörg.
Afiliação
  • Phattarapattamawong S; Department of Environmental Engineering, Faculty of Engineering, King Mongkut's University of Technology Thonburi, Bangkok, Thailandand Research Program in Control of Hazardous Contaminants in Raw Water Resources for Water Scarcity Resilience, Center of Excellence on Hazardous Substance Management (
  • Kaiser AM; Institute for Water Quality and Resource Management, TU Wien, Vienna, Austria.
  • Saracevic E; Institute for Water Quality and Resource Management, TU Wien, Vienna, Austria.
  • Schaar HP; Institute for Water Quality and Resource Management, TU Wien, Vienna, Austria.
  • Krampe J; Institute for Water Quality and Resource Management, TU Wien, Vienna, Austria.
Water Sci Technol ; 2017(2): 404-411, 2018 May.
Article em En | MEDLINE | ID: mdl-29851392
ABSTRACT
The study aims to simultaneously control micropollutants and bromate formations by using ozonation and peroxone process. The batch experiments were run with variations in specific ozone dose (SOD) and hydrogen peroxide-to-ozone (H2O2/O3) ratio. Based on the removal by ozonation and peroxone, micropollutants were categorized into three groups non-reactive compounds (i.e. amidotrizoate), moderately reactive compounds (i.e. metoprolol, acesulfame potassium, bezafibrate, and benzotriazole), and highly reactive compounds (i.e. carbamazepine and diclofenac). For ozonation and peroxone process, the removals for highly reactive compounds and moderately reactive compounds were 82-99% and 29-99%, respectively. The removal of amidotrizoate was not observed in this study. The effect of ozonation on micropollutant removals was similar to the peroxone process. However, differences in bromate formation were observed. Bromate formation depended on the SOD, while addition of hydrogen peroxide suppressed the bromate formation. The peroxone process at the H2O2/O3 ratio of 0.3 was recommended to bromide-containing water below 100 µg·L-1 for simultaneous control of micropollutants and bromate. Enhancement in micropollutant removals, except for the non-reactive groups, was achieved with either higher SOD or the addition of hydrogen peroxide to ozonation. The micropollutant removal predicted from the second-order kinetic reaction with ozone and •OH exposures was higher than the observed data.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ozônio / Ácidos Sulfúricos / Poluentes Químicos da Água / Bromatos / Eliminação de Resíduos Líquidos Idioma: En Revista: Water Sci Technol Assunto da revista: SAUDE AMBIENTAL / TOXICOLOGIA Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ozônio / Ácidos Sulfúricos / Poluentes Químicos da Água / Bromatos / Eliminação de Resíduos Líquidos Idioma: En Revista: Water Sci Technol Assunto da revista: SAUDE AMBIENTAL / TOXICOLOGIA Ano de publicação: 2018 Tipo de documento: Article