Treatment of the distal radius fractures with percutaneous pinning: evolution to the HK2 system.
Eur J Orthop Surg Traumatol
; 28(8): 1477-1485, 2018 Dec.
Article
em En
| MEDLINE
| ID: mdl-29869724
Displaced fractures of the distal radius often require reduction and fixation to improve outcome in active patients. The volar locking plate gained ground over pinning, which was the first surgical solution described. But pinning methods have since evolved with fewer complications. The authors present a clinical study of distal radius fracture fixation using the HK2 technique, where subchondral pins are connected to intra-focal pins. The results are satisfactory with a lower complication rate compared to other pinning methods. This technical improvement relaunches the pinning technique, with its two advantages, being faster and significantly cheaper than locking plates, with similar long-term functional results.
Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Complicações Pós-Operatórias
/
Rádio (Anatomia)
/
Fraturas do Rádio
/
Pinos Ortopédicos
/
Fios Ortopédicos
/
Fixação Interna de Fraturas
Tipo de estudo:
Diagnostic_studies
/
Observational_studies
/
Prognostic_studies
Limite:
Female
/
Humans
/
Male
/
Middle aged
País/Região como assunto:
Europa
Idioma:
En
Revista:
Eur J Orthop Surg Traumatol
Ano de publicação:
2018
Tipo de documento:
Article
País de afiliação:
França
País de publicação:
França