Your browser doesn't support javascript.
loading
Analysis of the microbial cell-Ab binding in buffer solution by the piezoelectric resonator.
Guliy, O I; Zaitsev, B D; Borodina, I A; Burygin, G L; Karavaeva, O A; Semyonov, A P.
Afiliação
  • Guliy OI; Institute of Biochemistry and Physiology of Plants and Microorganisms, RAS, 13 Prospect Entuziastov, Saratov, 410049, Russia; Saratov State Vavilov Agrarian University, Saratov, 410012, Russia. Electronic address: guliy_olga@mail.ru.
  • Zaitsev BD; Kotel'nikov Institute of Radio Engineering and Electronics of RAS, Saratov Branch, Saratov, 410019, Russia.
  • Borodina IA; Kotel'nikov Institute of Radio Engineering and Electronics of RAS, Saratov Branch, Saratov, 410019, Russia.
  • Burygin GL; Institute of Biochemistry and Physiology of Plants and Microorganisms, RAS, 13 Prospect Entuziastov, Saratov, 410049, Russia; Saratov State Vavilov Agrarian University, Saratov, 410012, Russia.
  • Karavaeva OA; Institute of Biochemistry and Physiology of Plants and Microorganisms, RAS, 13 Prospect Entuziastov, Saratov, 410049, Russia.
  • Semyonov AP; Kotel'nikov Institute of Radio Engineering and Electronics of RAS, Saratov Branch, Saratov, 410019, Russia.
Anal Biochem ; 554: 53-60, 2018 08 01.
Article em En | MEDLINE | ID: mdl-29870693
ABSTRACT
The possibility of the registration of the interaction of the cells Azospirillum lipoferum Sp59b with the specific antibodies directly in the conducting suspensions by using an acoustic sensor was shown. The main element of the sensor is a piezoelectric resonator with a lateral electric field. The analysis is based on a comparison of the resonator's electrical impedance before and after the specific biological interaction between the cells and antibodies. By using this sensor one can detect and identify the bacterial cells directly in the buffer solution with the conductivity between 2.4 and 20 µS/cm. The minimum detectable concentration of the bacterial cells turned out to be ∼103 cells/ml and for a short time (less than 10 min). Also the possibility of the detection of the cells in the presence of the extraneous microflora was shown. The results provide the opportunities for the development of a new class of the methods for the analysis of the microbial cells in real-time directly in the buffer solution.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Azospirillum lipoferum / Anticorpos Antibacterianos Idioma: En Revista: Anal Biochem Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Azospirillum lipoferum / Anticorpos Antibacterianos Idioma: En Revista: Anal Biochem Ano de publicação: 2018 Tipo de documento: Article