Your browser doesn't support javascript.
loading
The Impact of Three Different Wash Solutions on Autotransfusion Products.
Ratliff, Todd M; Burnside, Jeffery L; Hodge, Ashley B; Naguib, Aymen N; Gomez, Daniel.
Afiliação
  • Ratliff TM; The Heart Center at Nationwide Children's Hospital, Columbus, Ohio; and.
  • Burnside JL; The Heart Center at Nationwide Children's Hospital, Columbus, Ohio; and.
  • Hodge AB; The Heart Center at Nationwide Children's Hospital, Columbus, Ohio; and.
  • Naguib AN; Department of Anesthesiology and Pain Medicine, Nationwide Children's Hospital, Columbus, Ohio.
  • Gomez D; The Heart Center at Nationwide Children's Hospital, Columbus, Ohio; and.
J Extra Corpor Technol ; 50(2): 113-116, 2018 06.
Article em En | MEDLINE | ID: mdl-29921990
ABSTRACT
Many blood conservation techniques and strategies have been implemented to aid in decreasing the use of allogenic blood utilization during pediatric cardiothoracic surgery. Use of techniques, such as acute normovolemic hemodilution, retrograde autologous prime, venous autologous prime, and autotransfuion, may lead to a decrease in the need for allogenic blood products. Autotransfusion has become a standard of care for all cardiothoracic surgical procedures requiring cardiopulmonary bypass (CPB). Although widely used, there is still debate over which wash solution will produce the most physiologically normal autotransfusion product. Pediatric patients can be at a higher risk for electrolyte imbalance intraoperatively and postoperatively. In an attempt to minimize this, we sought out to evaluate three different wash solutions and how they would affect the final autotransfusion product. This comparison consisted of three wash solutions; .9% sodium chloride, Normosol-R™, and Plasma-Lyte A. Based on the evaluation of all wash solutions, Plasma-Lyte A produced the most physiological normal final autotransfusion product in regards to electrolytes.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Transfusão de Sangue Autóloga / Ponte Cardiopulmonar / Substitutos do Plasma Limite: Humans Idioma: En Revista: J Extra Corpor Technol Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Transfusão de Sangue Autóloga / Ponte Cardiopulmonar / Substitutos do Plasma Limite: Humans Idioma: En Revista: J Extra Corpor Technol Ano de publicação: 2018 Tipo de documento: Article