Your browser doesn't support javascript.
loading
[Application of RapidHIT™ 200 System in Forensic Medicine].
Sun, S; Tian, Y M; Tang, J M; Zhang, Q X; Hu, Y L; Wang, P F; Xue, L Y; Liu, L; Tang, H.
Afiliação
  • Sun S; Jinci College of Shanxi Medical University, Taiyuan 030025, China.
  • Tian YM; First Clinical Medical College of Shanxi Medical University, Taiyuan 030001, China.
  • Tang JM; Aksu District Public Security Bureau, Aksu 843000, China.
  • Zhang QX; Forensic Judicial Appraisal Center of Beijing Public Security Bureau, Beijing 100192, China.
  • Hu YL; Counter-narcotics Detachment of Ordos Public Security Bureau, Ordos 017000, China.
  • Wang PF; Tumoteyou Branch of Baotou Public Security Bureau, Baotou 014100, China.
  • Xue LY; Forensic Judicial Appraisal Center of Beijing Public Security Bureau, Beijing 100192, China.
  • Liu L; Forensic Judicial Appraisal Center of Beijing Public Security Bureau, Beijing 100192, China.
  • Tang H; Institute of Science and Identification, DIAN, Hangzhou 310030, China.
Fa Yi Xue Za Zhi ; 34(2): 161-164, 2018 04.
Article em Zh | MEDLINE | ID: mdl-29923383
ABSTRACT

OBJECTIVES:

To validate the analysis capability of RapidHIT™ 200 system for four kinds of routine forensic samples and the recyclable capability of template, template DNA and PCR products in the process of twice duplicate detection.

METHODS:

The buccal swabs underwent the test twice by RapidHIT™ 200 system, and the template DNA and PCR products that arose in the system were also tested for two times. After four kinds of routine forensic samples were detected by RapidHIT™ 200 system, the follow-up tests of the template, template DNA and PCR products that arose in the system were performed.

RESULTS:

The STR loci could be detected in the buccal swabs by the system for the first time. However, part of the STR loci lost during the second test. And the peak value obtained in the second test was significantly reduced than the one in the first time. The average STR loci detection rates of the template DNA and PCR products were both less than 50% in the second test, which were significantly reduced than that in the first test. In addition, the analysis capability of the system for the tissues and buccal swabs was better than that for the blood and cigarette butts. Compared with the first test, the STR loci detection rate of the tested items, template DNA and PCR products decreased with the numbers of tests.

CONCLUSIONS:

RapidHIT™ 200 system is more effective in retesting buccal swabs than other samples, whereas the items, DNA template, PCR products obtained in the first and second time cannot be directly used for the further application and study of forensic medicine.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Automação / Moldes Genéticos / Repetições de Microssatélites / Genética Forense Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: Zh Revista: Fa Yi Xue Za Zhi Assunto da revista: JURISPRUDENCIA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Automação / Moldes Genéticos / Repetições de Microssatélites / Genética Forense Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: Zh Revista: Fa Yi Xue Za Zhi Assunto da revista: JURISPRUDENCIA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: China