Your browser doesn't support javascript.
loading
Toward adaptive radiotherapy for lung patients: feasibility study on deforming planning CT to CBCT to assess the impact of anatomical changes on dosimetry.
Cole, A J; Veiga, C; Johnson, U; D'Souza, D; Lalli, N K; McClelland, J R.
Afiliação
  • Cole AJ; University College London Hospitals NHS Foundation Trust, 250 Euston Road, London, United Kingdom. St. Bartholomew's Hospital, West Smithfield, London, United Kingdom. Author to whom any correspondence should be addressed.
Phys Med Biol ; 63(15): 155014, 2018 08 01.
Article em En | MEDLINE | ID: mdl-29978832
Changes in lung architecture during a course of radiotherapy can alter the planned dose distribution to the extent that it becomes clinically unacceptable. This study aims to validate a quantitative method of determining whether a replan is required during the course of conformal radiotherapy. The proposed method uses deformable image registration (DIR) to flexibly map planning CT (pCT) data to the anatomy of online CBCT images. The resulting deformed CT (dCT) images are used as a basis for assessing the effect of anatomical change on dose distributions. The study used retrospective data from a sample of seven replanned lung patients. The settings of an in-house, open-source DIR algorithm were first optimised for CT-to-CBCT registrations of the anatomy of the thorax. Using these optimised parameters, each patient's pCT was deformed to the CBCT acquired immediately before the replan. Registration accuracy was rigorously validated both geometrically and dosimetrically to confirm that the dCTs could reliably be used to inform replan decisions. A retrospective evaluation of the changes in dose delivered over time was then carried out for a single patient to demonstrate the clinical application of the proposed method. The geometric analysis showed good agreement between deformed structures and those same structures manually outlined on the CBCT images. Results were consistently better than those achieved with rigid-only registration. In the dosimetric analysis, dose distributions derived from the dCTs were found to match closely to the 'gold standard' replan CT (rCT) distributions across dose volume histogram and absolute dose difference measures. The retrospective analysis of serial CBCTs of a single patient produced reliable quantitative assessment of the dose delivery. Had the proposed method been available at the time of treatment, it would have enabled a more objective replan decision. DIR is a valuable clinical tool for dose recalculation in adaptive radiotherapy protocols for lung cancer patients.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Planejamento da Radioterapia Assistida por Computador / Radioterapia Conformacional / Tomografia Computadorizada de Feixe Cônico Espiral / Neoplasias Pulmonares Tipo de estudo: Guideline / Prognostic_studies Limite: Female / Humans / Male / Middle aged Idioma: En Revista: Phys Med Biol Ano de publicação: 2018 Tipo de documento: Article País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Planejamento da Radioterapia Assistida por Computador / Radioterapia Conformacional / Tomografia Computadorizada de Feixe Cônico Espiral / Neoplasias Pulmonares Tipo de estudo: Guideline / Prognostic_studies Limite: Female / Humans / Male / Middle aged Idioma: En Revista: Phys Med Biol Ano de publicação: 2018 Tipo de documento: Article País de publicação: Reino Unido