Your browser doesn't support javascript.
loading
Measuring pressure pain threshold in the cervical region of dizzy patients-The reliability of a pressure algometer.
Knapstad, Mari Kalland; Nordahl, Stein Helge Glad; Naterstad, Ingvill Fjell; Ask, Tove; Skouen, Jan Sture; Goplen, Frederik Kragerud.
Afiliação
  • Knapstad MK; Norwegian National Advisory Unit on Vestibular Disorders, Department of Otorhinolaryngology/Head and Neck Surgery, Haukeland University Hospital, Bergen, Norway.
  • Nordahl SHG; Department of Clinical Medicine, University of Bergen, Bergen, Norway.
  • Naterstad IF; Norwegian National Advisory Unit on Vestibular Disorders, Department of Otorhinolaryngology/Head and Neck Surgery, Haukeland University Hospital, Bergen, Norway.
  • Ask T; Department of Clinical Medicine, University of Bergen, Bergen, Norway.
  • Skouen JS; Department of Global Public Health and Primary Care, University of Bergen, Bergen, Norway.
  • Goplen FK; The Outpatient Spine Clinic, Department of Physiotherapy, Haukeland University Hospital, Bergen, Norway.
Physiother Res Int ; 23(4): e1736, 2018 Oct.
Article em En | MEDLINE | ID: mdl-30088327
ABSTRACT

OBJECTIVES:

A tool for measuring neck pain in patients with dizziness is needed to further investigate the relationship between the two symptoms. The objective of this study was to examine the reliability and validity of a hand-held pressure algometer in measuring pressure pain threshold (PPT) in different cervical regions of dizzy patients.

METHODS:

PPT was measured at two bilateral standardized sites of the neck by a trained physiotherapist in 50 patients with dizziness. Intraclass correlation coefficients (ICC) were calculated for intrarater and test-retest reliability. Concurrent validity was assessed by measuring the association between PPT and the American College of Rheumatology (ACR) tender points at each site and with the numeric pain rating scale (NPRS).

RESULTS:

Almost perfect intrarater (ICC = 0.815-0.940) and within-session test-retest (ICC = 0.854-0.906) reliability was found between the measures. On each site, a low PPT predicted a positive ACR tender point at each site (OR = 0.864-0.922). Last, we found a statistical inverse relationship between the PPT and the NPRS (R = -0.52 to -0.66).

CONCLUSION:

The study shows that a pressure algometer is a reliable tool for measuring PPT in the neck of dizzy patients. Further, the PPT correlates significantly with other subjective measures of pain indicating that it may be a useful tool for further research.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Medição da Dor / Cervicalgia / Tontura Tipo de estudo: Prognostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Physiother Res Int Assunto da revista: REABILITACAO Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Noruega

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Medição da Dor / Cervicalgia / Tontura Tipo de estudo: Prognostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Physiother Res Int Assunto da revista: REABILITACAO Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Noruega