Your browser doesn't support javascript.
loading
Novel Technologies Found to be Valid and Reliable for the Measurement of Vertical Jump Height With Jump-and-Reach Testing.
Brooks, Edward R; Benson, Amanda C; Bruce, Lyndell M.
Afiliação
  • Brooks ER; Center for Sports Research, School of Exercise and Nutrition Sciences, Deakin University, Burwood, Victoria, Australia.
  • Benson AC; School of Health and Biomedical Sciences, RMIT University, Bundoora, Victoria, Australia.
  • Bruce LM; Department of Health and Medical Sciences, Swinburne University, Hawthorn, Victoria, Australia.
J Strength Cond Res ; 32(10): 2838-2845, 2018 Oct.
Article em En | MEDLINE | ID: mdl-30113913
ABSTRACT
Brooks, ER, Benson, AC, and Bruce, LM. Novel technologies found to be valid and reliable for the measurement of vertical jump height with jump-and-reach testing. J Strength Cond Res 32(10) 2838-2845, 2018-Vertical jump testing is used by coaches and athletes across many sports and disciplines to assess lower-body power and neuromuscular fatigue. A range of devices are available to measure jump height, with recent innovations attempting to improve portability, usability, and accessibility. New devices should be evaluated for their effectiveness and dependability in specific tests before being adopted. The purpose of this study was to assess the validity and reliability of 2 novel measurement devices for jump height testing with a jump-and-reach protocol. Twenty-six healthy, active adults participated during 2 testing occasions. A wearable inertial measurement unit (VERT) and a smart device application (My Jump 2) were compared with established measures (force platform and jump-and-reach apparatus [Yardstick]). Correlations between the VERT and force platform were r = 0.95 (90% confidence interval [CI] 0.93-0.97), and r = 0.93 (90% CI 0.90-0.95) for the Yardstick. Correlations between the My Jump 2 app and force platform were r = 0.98 (90% CI 0.97-0.99), and r = 0.94 (90% CI 0.92-0.96) for the Yardstick. Reliability, measured as intraclass correlation coefficient (ICC), was 0.91 (90% CI 0.87-0.94) for the VERT, and 0.97 (90% CI 0.96-0.98) for the My Jump 2 app. Intrarater reliability for the My Jump 2 app was ICC = 0.99 (90% CI 0.99-0.99). The VERT and the My Jump 2 app have both shown acceptable validity and reliability compared with both the force platform and Yardstick. However, practitioners should consider which measurement device/s to use based on the acceptable level of potential error for their population and testing objectives.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Teste de Esforço / Desempenho Atlético Limite: Adult / Female / Humans / Male Idioma: En Revista: J Strength Cond Res Assunto da revista: FISIOLOGIA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Austrália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Teste de Esforço / Desempenho Atlético Limite: Adult / Female / Humans / Male Idioma: En Revista: J Strength Cond Res Assunto da revista: FISIOLOGIA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Austrália
...