Your browser doesn't support javascript.
loading
Development and application of a method for discriminating the influence of radon progenies in air from aerial radiation monitoring data.
Hirouchi, Jun; Nishizawa, Yukiyasu; Urabe, Yoshimi; Shimada, Kazumasa; Sanada, Yukihisa; Munakata, Masahiro.
Afiliação
  • Hirouchi J; Nuclear Safety Research Center, Japan Atomic Energy Agency, 2-4 Shirane Shirakata, Tokai-mura, Naka-gun, Ibaraki 3191195, Japan. Electronic address: hirouchi.jun@jaea.go.jp.
  • Nishizawa Y; OYO Corporation, 1-66-22 Miyahara-cho, Kita-ku, Saitama-shi, Saitama 3310812, Japan.
  • Urabe Y; NESIInc., 38 Shinko-cho, Hitachinaka, Ibaraki 3120005, Japan.
  • Shimada K; Nuclear Safety Research Center, Japan Atomic Energy Agency, 2-4 Shirane Shirakata, Tokai-mura, Naka-gun, Ibaraki 3191195, Japan.
  • Sanada Y; Fukushima Remote Monitoring Group, Fukushima Environmental Safety Center, Japan Atomic Energy Agency, 45-169 Sukakeba, Kaihama-aza, Haramachi-ku, Minamisoma-shi 9750036, Japan.
  • Munakata M; Nuclear Safety Research Center, Japan Atomic Energy Agency, 2-4 Shirane Shirakata, Tokai-mura, Naka-gun, Ibaraki 3191195, Japan.
Appl Radiat Isot ; 141: 122-129, 2018 Nov.
Article em En | MEDLINE | ID: mdl-30237095
The influence of gamma-rays from natural nuclides (particularly the radon progenies, 214Pb and 214Bi) must be excluded from aerial radiation monitoring (ARM) data to accurately estimate the deposition of artificial radionuclides. A method for discriminating the influence of the radon progenies in air from the ARM data was developed. Two types of detectors with different crystal sizes were installed in a helicopter. The gamma-ray responses of these detectors were simulated using EGS5. The influence of the radon progenies in air was excluded using the relation between the count rates of six NaI (Tl) detectors and a LaBr3 detector. The discrimination method was applied to the ARM data obtained from around the Sendai and Fukushima Dai-ichi Nuclear Power Stations. To verify the validity of the discrimination method, the dose rate estimated from the ARM data was compared with the dose rate measured using a NaI survey meter at a height of 1 m above the ground. The application of the discrimination method improved the dose rate estimation, showing the validity of the discrimination method.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Revista: Appl Radiat Isot Assunto da revista: MEDICINA NUCLEAR / SAUDE AMBIENTAL Ano de publicação: 2018 Tipo de documento: Article País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Revista: Appl Radiat Isot Assunto da revista: MEDICINA NUCLEAR / SAUDE AMBIENTAL Ano de publicação: 2018 Tipo de documento: Article País de publicação: Reino Unido