Your browser doesn't support javascript.
loading
X-ray Microtomography of Intermittency in Multiphase Flow at Steady State Using a Differential Imaging Method.
Gao, Ying; Lin, Qingyang; Bijeljic, Branko; Blunt, Martin J.
Afiliação
  • Gao Y; Department of Earth Science and Engineering Imperial College London London UK.
  • Lin Q; Qatar Carbonates and Carbon Storage Research Centre, Department of Earth Science and Engineering Imperial College London London UK.
  • Bijeljic B; Department of Earth Science and Engineering Imperial College London London UK.
  • Blunt MJ; Department of Earth Science and Engineering Imperial College London London UK.
Water Resour Res ; 53(12): 10274-10292, 2017 Dec.
Article em En | MEDLINE | ID: mdl-30333671
We imaged the steady state flow of brine and decane in Bentheimer sandstone. We devised an experimental method based on differential imaging to examine how flow rate impacts impact the pore-scale distribution of fluids during coinjection. This allows us to elucidate flow regimes (connected, or breakup of the nonwetting phase pathways) for a range of fractional flows at two capillary numbers, Ca, namely 3.0 × 10-7 and 7.5 × 10-6. At the lower Ca, for a fixed fractional flow, the two phases appear to flow in connected unchanging subnetworks of the pore space, consistent with conventional theory. At the higher Ca, we observed that a significant fraction of the pore space contained sometimes oil and sometimes brine during the 1 h scan: this intermittent occupancy, which was interpreted as regions of the pore space that contained both fluid phases for some time, is necessary to explain the flow and dynamic connectivity of the oil phase; pathways of always oil-filled portions of the void space did not span the core. This phase was segmented from the differential image between the 30 wt % KI brine image and the scans taken at each fractional flow. Using the grey scale histogram distribution of the raw images, the oil proportion in the intermittent phase was calculated. The pressure drops at each fractional flow at low and high flow rates were measured by high-precision differential pressure sensors. The relative permeabilities and fractional flow obtained by our experiment at the mm-scale compare well with data from the literature on cm-scale samples.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Water Resour Res Ano de publicação: 2017 Tipo de documento: Article País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Water Resour Res Ano de publicação: 2017 Tipo de documento: Article País de publicação: Estados Unidos