Your browser doesn't support javascript.
loading
Chitosan­g­maleic acid for effective removal of copper and nickel ions from their solutions.
Ibrahim, Ahmed G; Saleh, Alaaeldine Sh; Elsharma, Emad M; Metwally, Essam; Siyam, Tharwat.
Afiliação
  • Ibrahim AG; Laboratory of Polymers, Department of Chemistry, Faculty of Science, Al-Azhar University, Nasr City, Cairo, Egypt. Electronic address: ahmed_polytech@azhar.edu.eg.
  • Saleh AS; Nuclear Chemistry Department, Hot Laboratories Center, Atomic Energy Authority, Inshas, Cairo 13759, Egypt.
  • Elsharma EM; Nuclear Chemistry Department, Hot Laboratories Center, Atomic Energy Authority, Inshas, Cairo 13759, Egypt.
  • Metwally E; Nuclear Chemistry Department, Hot Laboratories Center, Atomic Energy Authority, Inshas, Cairo 13759, Egypt.
  • Siyam T; Nuclear Chemistry Department, Hot Laboratories Center, Atomic Energy Authority, Inshas, Cairo 13759, Egypt.
Int J Biol Macromol ; 121: 1287-1294, 2019 Jan.
Article em En | MEDLINE | ID: mdl-30340005
Pollution of the environment associated with discharging the toxic heavy metals in water makes us focus the light to solve this problem. In continuation of our efforts, we aim in this work to utilize the graft copolymer (chitosan­g­maleic acid) to purify water from copper and nickel ions. The graft copolymer has been synthesized using gamma radiation and the grafting conditions have been optimized by studying the influence of acetic acid concentration (0.5-10% V/V), monomer concentration (5-17.5% w/v), chitosan concentration (0.25-2.5% w/v) and absorbed dose (0.5-5 kGy). FT-IR and TGA have been employed to characterize the graft copolymer. The metal ions uptake by the prepared graft copolymer was investigated and the influence of contact time, solution pH, polymer concentration, and metal ion concentration was studied. Adsorption kinetic models (pseudo-first-order, pseudo-second-order, and intra-particle diffusion equations) and adsorption isotherms (Langmuir, Freundlich, and Temkin equations) were also studied. It was found that the adsorption kinetics and isotherm agreed well with pseudo-second-order and Langmuir equations, respectively, indicating that the adsorption was chemisorption. The adsorption capacities of CTS­g­MA were 312.4 mg g-1 and 70.1 mg g-1 for Cu2+ and Ni2+, respectively. Effect of co-existence of other cationic ions on the adsorption capacity was also investigated.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Purificação da Água / Cobre / Quitosana / Maleatos / Níquel Tipo de estudo: Prognostic_studies Idioma: En Revista: Int J Biol Macromol Ano de publicação: 2019 Tipo de documento: Article País de publicação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Purificação da Água / Cobre / Quitosana / Maleatos / Níquel Tipo de estudo: Prognostic_studies Idioma: En Revista: Int J Biol Macromol Ano de publicação: 2019 Tipo de documento: Article País de publicação: Holanda