Your browser doesn't support javascript.
loading
Multipoint vertical-Thomson scattering diagnostic on HL-2A tokamak.
Huang, Y; Wang, Y Q; Hou, Z P; Ren, L L; Liu, C H; Feng, Z; Luo, C W.
Afiliação
  • Huang Y; Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041, China.
  • Wang YQ; Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041, China.
  • Hou ZP; Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041, China.
  • Ren LL; Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041, China.
  • Liu CH; Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041, China.
  • Feng Z; Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041, China.
  • Luo CW; Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041, China.
Rev Sci Instrum ; 89(10): 10C116, 2018 Oct.
Article em En | MEDLINE | ID: mdl-30399663
ABSTRACT
Some progress has been made to develop the multipoint Thomson scattering (TS) diagnostic for the HL-2A tokamak physics experiments. Hardware of silicon avalanche photodiode detector electronics is improved, which provides two output signal channels. In one channel, only the rapid TS signal is the output after deducting the influence of the background slow-varying plasma light. In the other, both the rapid TS signal and the plasma background signal are the output. In the latest HL-2A experiment campaign, the newly developed electronics are tested and TS signals can be obtained from each of the two channels, where the signal is digitized by 12-bit transient recorder sampled at 1 GS/s. Laser beam alignment is fulfilled by using motorized stages to control the laser beam passing through ∼10 mm-wide narrow throats of the lower and upper closed divertors with small movements and then the stray laser light is reduced. New modules of fast digitizers with more than 100 channels are installed and will be used to record TS pulse signals. On the basis of these achievements, about 15-point measurements of plasma electron temperature and density by Thomson scattering diagnostic will come into operation in the upcoming HL-2A experiment campaign.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2018 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2018 Tipo de documento: Article País de afiliação: China