Your browser doesn't support javascript.
loading
Pharmacokinetic study of sirolimus ophthalmic formulations by consecutive sampling and liquid chromatography-tandem mass spectrometry.
Wang, Ling; Tang, Zhan; Shi, Ming; Wang, Qiao.
Afiliação
  • Wang L; Department of Pharmaceutics, Institute of Metaria Medica, Zhejiang Academy of Medical Sciences, Hangzhou, 310013, PR China.
  • Tang Z; Department of Pharmaceutics, Institute of Metaria Medica, Zhejiang Academy of Medical Sciences, Hangzhou, 310013, PR China.
  • Shi M; The Drug analysis laboratory of Hangzhou GuGe Pharmaceutical Development Co., Ltd., Hangzhou, 310013, PR China.
  • Wang Q; Department of Pharmaceutics, Institute of Metaria Medica, Zhejiang Academy of Medical Sciences, Hangzhou, 310013, PR China. Electronic address: wangqiao-1@163.com.
J Pharm Biomed Anal ; 164: 337-344, 2019 Feb 05.
Article em En | MEDLINE | ID: mdl-30415142
ABSTRACT
Sirolimus is regarded as one of the most effective immunosuppressants receiving extensive attention over the years, for which the ocular application needs further development in clinical keratoplasty. In order to study the transcorneal absorption effect of ophthalmic administration, there was a need to study the pharmacokinetics of drugs in aqueous humor. In this work, a validated and reliable HPLC-ESI-MS/MS method was established to study the pharmacokinetics of sirolimus nanoformulations in rabbit aqueous humor. The analysis conditions were as follows. Ascomycin was chosen as internal standard. After a simple precipitation extraction procedure, the aqueous humor samples were separated on a XBridge C18 column (4.6 mm × 150 mm, 3.5 µm, Waters Co., USA) with a mobile phase comprised of water (0.1% formic acid and 5 mM ammonium formate) and methanol (0.1% formic acid) at the ratio of 1090 (v/v). The mass analysis was achieved by positive ionization with multiple reaction monitoring (MRM) mode. The highest response ion pairs m/z at 931.5→864.5 were chosen for sirolimus. The validated results showed that the calibration range was 0.3-100.6 ng/mL with r = 0.9997 (n = 6). The R.S.D. values of the intra- and inter-day precision were less than 11% and the average accuracy values were between 94.73%-100.20%. Besides, for reducing the consumption of rabbits and the variation of the data, we designed a consecutive sampling method in pharmacokinetic study, with only seven rabbits consumed for each formulation. In conclusion, the developed analysis method was more reliable and practical than previously reported experiments. Meanwhile, the validated method was successfully applied to study the pharmacokinetics of sirolimus micelle and sirolimus nanosuspension after ophthalmic administration.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Humor Aquoso / Sirolimo / Espectrometria de Massas em Tandem / Imunossupressores Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Animals Idioma: En Revista: J Pharm Biomed Anal Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Humor Aquoso / Sirolimo / Espectrometria de Massas em Tandem / Imunossupressores Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Animals Idioma: En Revista: J Pharm Biomed Anal Ano de publicação: 2019 Tipo de documento: Article