Your browser doesn't support javascript.
loading
Chronic Intracortical Recording and Electrochemical Stability of Thiol-ene/Acrylate Shape Memory Polymer Electrode Arrays.
Stiller, Allison M; Usoro, Joshua; Frewin, Christopher L; Danda, Vindhya R; Ecker, Melanie; Joshi-Imre, Alexandra; Musselman, Kate C; Voit, Walter; Modi, Romil; Pancrazio, Joseph J; Black, Bryan J.
Afiliação
  • Stiller AM; Department of Bioengineering, The University of Texas at Dallas, Richardson, TX 75080, USA. Allison.stiller@utdallas.edu.
  • Usoro J; Department of Bioengineering, The University of Texas at Dallas, Richardson, TX 75080, USA. Joshua.usoro@utdallas.edu.
  • Frewin CL; Department of Bioengineering, The University of Texas at Dallas, Richardson, TX 75080, USA. Christopher.frewin@utdallas.edu.
  • Danda VR; Department of Bioengineering, The University of Texas at Dallas, Richardson, TX 75080, USA. vxd160030@utdallas.edu.
  • Ecker M; Qualia, Inc., Dallas, TX 75252, USA. vxd160030@utdallas.edu.
  • Joshi-Imre A; Department of Materials Science and Engineering, The University of Texas at Dallas, Richardson, TX 75080, USA. Melanie.ecker@utdallas.edu.
  • Musselman KC; Department of Bioengineering, The University of Texas at Dallas, Richardson, TX 75080, USA. Alexandra.Joshi-imre@utdallas.edu.
  • Voit W; Department of Bioengineering, The University of Texas at Dallas, Richardson, TX 75080, USA. kate.musselman@utdallas.edu.
  • Modi R; Qualia, Inc., Dallas, TX 75252, USA. walter.voit@utdallas.edu.
  • Pancrazio JJ; Department of Materials Science and Engineering, The University of Texas at Dallas, Richardson, TX 75080, USA. walter.voit@utdallas.edu.
  • Black BJ; Qualia, Inc., Dallas, TX 75252, USA. romil@qualiamedical.com.
Micromachines (Basel) ; 9(10)2018 Sep 29.
Article em En | MEDLINE | ID: mdl-30424433
ABSTRACT
Current intracortical probe technology is limited in clinical implementation due to the short functional lifetime of implanted devices. Devices often fail several months to years post-implantation, likely due to the chronic immune response characterized by glial scarring and neuronal dieback. It has been demonstrated that this neuroinflammatory response is influenced by the mechanical mismatch between stiff devices and the soft brain tissue, spurring interest in the use of softer polymer materials for probe encapsulation. Here, we demonstrate stable recordings and electrochemical properties obtained from fully encapsulated shape memory polymer (SMP) intracortical electrodes implanted in the rat motor cortex for 13 weeks. SMPs are a class of material that exhibit modulus changes when exposed to specific conditions. The formulation used in these devices softens by an order of magnitude after implantation compared to its dry, room-temperature modulus of ~2 GPa.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Micromachines (Basel) Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Micromachines (Basel) Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Estados Unidos
...